Test–Retest Reliability of the Functional Electromechanical Dynamometer for Squat Exercise
Indya del-Cuerpo,
Daniel Jerez-Mayorga,
Pedro Delgado-Floody (),
María Dolores Morenas-Aguilar and
Luis Javier Chirosa-Ríos
Additional contact information
Indya del-Cuerpo: Strength & Conditioning Laboratory, CTS-642 Research Group, Department of Physical Education and Sports, Faculty of Sports Sciences, University of Granada, 18071 Granada, Spain
Daniel Jerez-Mayorga: Strength & Conditioning Laboratory, CTS-642 Research Group, Department of Physical Education and Sports, Faculty of Sports Sciences, University of Granada, 18071 Granada, Spain
Pedro Delgado-Floody: Strength & Conditioning Laboratory, CTS-642 Research Group, Department of Physical Education and Sports, Faculty of Sports Sciences, University of Granada, 18071 Granada, Spain
María Dolores Morenas-Aguilar: Strength & Conditioning Laboratory, CTS-642 Research Group, Department of Physical Education and Sports, Faculty of Sports Sciences, University of Granada, 18071 Granada, Spain
Luis Javier Chirosa-Ríos: Strength & Conditioning Laboratory, CTS-642 Research Group, Department of Physical Education and Sports, Faculty of Sports Sciences, University of Granada, 18071 Granada, Spain
IJERPH, 2023, vol. 20, issue 2, 1-13
Abstract:
Background: the main objective of this study was to evaluate the test-retest reliability of two different functional electromechanical dynamometry (FEMD)-controlled squat training protocols. Methods: twenty-eight healthy young adults volunteered to participate in this study. They attended the laboratory on four different days and performed four sessions: two of three sets of 12 repetitions at 75% 1RM and two of three sets of 30 repetitions at 50% 1RM. The range of movement (ROM), mean dynamic strength (MDS), peak dynamic strength (PDS), mean velocity (MV), peak velocity (PV), mean potency (MP), peak potency (PP), work (W), and impulse (I) were recorded. To evaluate the reliability of FEMD, the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV) were obtained. Results: reliability was very high for ROM (CV: 3.72%, ICC: 0.95), MDS (CV: 1.09%, ICC: 1.00), PDS (CV: 1.97%, ICC: 1.00), and W (CV: 4.69%, ICC: 1.00) conditions at 50% 1RM and for ROM (CV: 3.90%, ICC: 0.95), MDS (CV: 0.52, ICC: 1.00), PDS (CV: 1.49%, ICC: 0.98), and W (CV: 4.14%, ICC: 1.00) conditions at 75% 1RM and high for the rest of variables at 50 and 75% 1RM. Conclusions: this study demonstrates that FEMD is a reliable instrument to measure ROM, MDS, PDS, MV, PV, PV, MP, MP, W, and I during both squat protocols (50 and 75% 1RM) in healthy young adults.
Keywords: reproducibility; muscle strength; dynamometer; isokinetic (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1660-4601/20/2/1289/pdf (application/pdf)
https://www.mdpi.com/1660-4601/20/2/1289/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:20:y:2023:i:2:p:1289-:d:1031686
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().