EconPapers    
Economics at your fingertips  
 

Test-Retest Reliability and Minimum Difference Values of a Novel and Portable Upright Row Strength Assessment in Probation Officers

Nicholas A. Buoncristiani, Jacob A. Mota, Gena R. Gerstner, Hayden K. Giuliani-Dewig and Eric D. Ryan ()
Additional contact information
Nicholas A. Buoncristiani: Neuromuscular Assessment Laboratory, Department of Exercise and Sport Science, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
Jacob A. Mota: Department of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX 79430, USA
Gena R. Gerstner: Neuromuscular Assessment Laboratory, Department of Exercise and Sport Science, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
Hayden K. Giuliani-Dewig: Human Performance Innovation Center, Rockefeller Neuroscience Institute, West Virginia University, Morgantown, WV 26505, USA
Eric D. Ryan: Neuromuscular Assessment Laboratory, Department of Exercise and Sport Science, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA

IJERPH, 2023, vol. 20, issue 3, 1-6

Abstract: Upper body (UB) strength is important for occupational tasks and injury prevention in law enforcement officers (LEOs). Portable, reliable, and cost-effective assessments are needed to examine UB strength among LEOs in field settings. The purpose of this study was to examine the test-retest reliability and minimum difference (MD) values of a novel and portable isometric upright row assessment in probation officers. Thirty certified probation officers (18 women; age = 38.9 ± 9.0 years, body mass = 98.8 ± 27.1 kg, stature = 171.4 ± 14.0 cm) volunteered for this investigation. Testing occurred on-site across two sessions (2–5 days apart). Participants stood upon an aluminum plate with a chain attached to a handle and dynamometer. They grasped the handle with a pronated grip, two cm below the umbilicus, and performed three isometric maximal voluntary contractions. Intraclass correlation coefficient (ICC2,1), standard error of the measurement (SEM), and MD values were calculated. Results indicated no significant systematic error ( p = 0.080) across sessions. The ICC2,1, SEM, and MD values for UB strength were 0.984, 27.20 N (4.1% of the mean), and 75.38 N (11.3% of the mean), respectively. These data suggest this isometric upright row assessment is a reliable, portable, and cost-effective measure of UB strength to assess and monitor LEOs in field settings.

Keywords: isometric peak force; upper body strength; tactical; law enforcement officers (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2023
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1660-4601/20/3/2236/pdf (application/pdf)
https://www.mdpi.com/1660-4601/20/3/2236/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:20:y:2023:i:3:p:2236-:d:1047765

Access Statistics for this article

IJERPH is currently edited by Ms. Jenna Liu

More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jijerp:v:20:y:2023:i:3:p:2236-:d:1047765