Enamel Analysis by 3D Scanning after Three Orthodontic Clean-Up Procedures: An In-Vitro Test of a New Piezoelectric Tool
Gianna Maria Nardi,
Marta Mazur (),
Roberta Grassi,
Serena Rifuggiato,
Vito Stiuso,
Joanna Janiszewska-Olszowska,
Livia Ottolenghi,
Ersilia Barbato,
Paolo Minetola and
Luca Iuliano
Additional contact information
Gianna Maria Nardi: Department of Odontostomatological and Maxillofacial Sciences, Sapienza University of Rome, 00161 Rome, Italy
Marta Mazur: Department of Odontostomatological and Maxillofacial Sciences, Sapienza University of Rome, 00161 Rome, Italy
Roberta Grassi: Department of Oral Surgery, Tor Vergata University, 00100 Rome, Italy
Serena Rifuggiato: Department of Management and Production Engineering, Politecnico di Torino, 10129 Torino, Italy
Vito Stiuso: Department of Management and Production Engineering, Politecnico di Torino, 10129 Torino, Italy
Joanna Janiszewska-Olszowska: Department of Interdisciplinary Dentistry, Pomeranian Medical University in Szczecin, 70-111 Szczecin, Poland
Livia Ottolenghi: Department of Odontostomatological and Maxillofacial Sciences, Sapienza University of Rome, 00161 Rome, Italy
Ersilia Barbato: Department of Odontostomatological and Maxillofacial Sciences, Sapienza University of Rome, 00161 Rome, Italy
Paolo Minetola: Department of Management and Production Engineering, Politecnico di Torino, 10129 Torino, Italy
Luca Iuliano: Department of Management and Production Engineering, Politecnico di Torino, 10129 Torino, Italy
IJERPH, 2023, vol. 20, issue 3, 1-14
Abstract:
(1) Background: To assess the clinical safety and efficacy of a new piezoelectric instrument for orthodontic clean-up; (2) Methods: An in-vitro comparative study on 75 teeth extracted for orthodontic reasons compared the tested method (Treatment 1) with two other procedures: One step finisher and polisher (Inverted cone One gloss Shofu Dental, Kyoto, Japan) (Treatment 2) and twelve-fluted tungsten carbide bur (123-603-00, Dentaurum, Pforzheim, Germany) and Sof-Lex discs Pop-On XT Kit (3M ESPE) (Treatment 3), with n:25 samples in each group. Clinical safety (enamel volume loss) and effectiveness (residual adhesive volume) were assessed using the structured light 3D scanner Atos Compact Scan (GOM GmbH) together with the support of Atos Professional software. The surfaces were scanned three times to assess: (i) the volume of the residual adhesive (RAV) after bracket removal; (ii) the volume of the relative residual adhesive ( dAV ) after the clean-up procedure; (iii) volume of the enamel loss (EVL); (3) Results: The mean RAV (mm 3 ) was 0.239 ± 0.337; 0.069 ± 0.124, 0.120 ± 0.193 and the mean EVL (mm 3 ) was 0.1870 ± 0.177, 0.187 ± 0.299 and 0.290 ± 0.205, for treatment 1, 2 and 3, respectively. The distribution was asymmetrical between groups in both cases; (4) Conclusions: The tested instrument proved to be effective and safe for post-orthodontic clean-up. With the increasing use of invisible aligners, the possibility of using an ergonomic and fast instrument is of benefit to both patient and practitioner.
Keywords: prevention; orthodontic clean-up; orthodontic debonding; 3D scanner; residual adhesive removal; enamel damage (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1660-4601/20/3/2516/pdf (application/pdf)
https://www.mdpi.com/1660-4601/20/3/2516/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:20:y:2023:i:3:p:2516-:d:1052654
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().