Study of Windlass Mechanism in the Lower Limb Using Inertial Sensors
María José Manfredi-Márquez,
Sandra Priscila Tavara-Vidalón,
Natalia Tavaruela-Carrión,
María Ángeles Gómez Benítez,
Lourdes María Fernandez-Seguín () and
Javier Ramos-Ortega
Additional contact information
María José Manfredi-Márquez: Podiatry Department, University of Seville, 41004 Sevilla, Spain
Sandra Priscila Tavara-Vidalón: Podiatry Department, University of Seville, 41004 Sevilla, Spain
Natalia Tavaruela-Carrión: Podiatry Department, University of Seville, 41004 Sevilla, Spain
María Ángeles Gómez Benítez: Podiatry Department, University of Seville, 41004 Sevilla, Spain
Lourdes María Fernandez-Seguín: Physiotherapy Department, University of Seville, 41009 Sevilla, Spain
Javier Ramos-Ortega: Podiatry Department, University of Seville, 41004 Sevilla, Spain
IJERPH, 2023, vol. 20, issue 4, 1-8
Abstract:
Aims: This study aimed to quantify the degrees of movement that occur in the lower limb using a kinematic system after taking two measurements of 45° and 60° of extension at the first metatarsophalangeal joint (1st MTPJ) and to test the validity of this sensor system using radiography. Methodology: This was a quasi-experimental test-post-test study with a single intervention group (25 subjects). Four inertial sensors were placed on the proximal phalange of the first toe, dorsum of the foot, medial-lateral of the leg (level of tibia), and medial-lateral of the thigh (level of femur). The extension of the 1st MTPJ produced movements of supination in the foot and rotation at the level of leg and thigh. We studied this mechanism in three situations (relaxed, 45°, and 60°) both with the sensors and with X-rays. Results: With the kinematic system, there was an increase in the range of movement in each of the variables, with a value of p < 0.05. The relationship between the kinematic system and the radiography was tested using Spearman’s rho test, obtaining a correlation coefficient of 0.624 and a value of p < 0.05, and the Bland–Altman graph, with 90% of the cases within the tolerance limits. Conclusions: The extension of the 1st MTPJ generated kinematic changes associated with supination movement in the midfoot and external rotation on the tibia and femur level. Both measurement techniques were very similar in the way that they quantified the degrees of extension of the 1st MTPJ. If we extrapolate this result to the measurement technique used by the inertial sensors, we could affirm that the values recorded in the supination and external rotation movements were reliable.
Keywords: windlass mechanism; inertial sensors; radiographic angles; 1st metatarsophalangeal joint; lower-limbs kinematics (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2023
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1660-4601/20/4/3220/pdf (application/pdf)
https://www.mdpi.com/1660-4601/20/4/3220/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:20:y:2023:i:4:p:3220-:d:1066054
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().