Coupling Effect Suppressed Compact Surgical Robot with 7-Axis Multi-Joint Using Wire-Driven Method
Kicheol Yoon,
Sung-Min Cho and
Kwang Gi Kim
Additional contact information
Kicheol Yoon: Department of Biomedical Engineering, College of Medicine, Gachon University, 38-13, Dokjom-ro 3, Namdong-gu, Incheon 21565, Korea
Sung-Min Cho: Department of Biomedical Engineering, College of Medicine, Gachon University, 38-13, Dokjom-ro 3, Namdong-gu, Incheon 21565, Korea
Kwang Gi Kim: Department of Biomedical Engineering, College of Medicine, Gachon University, 38-13, Dokjom-ro 3, Namdong-gu, Incheon 21565, Korea
Mathematics, 2022, vol. 10, issue 10, 1-17
Abstract:
Currently, the most prevalent surgical treatment method is laparoscopic surgery. Robotic surgery has many advantages over laparoscopic surgery. Therefore, robotic surgery technology is currently constantly evolving. The advantages of robotic surgery are that it can minimize incision, bleeding, and sequelae. Other advantages of robotic surgery are that it can reduce hospitalization, recovery period, and side effects. The appeal of robotic surgery is that it requires fewer surgical personnel compared to laparoscopic surgery. This paper proposes an ultra-compact 7-axis vertical multi-joint robot that employs the wire-driven method for minimally invasive surgery. The proposed robot analyzes the degree of freedom and motion coupling for control. The robot joint is composed of a total of seven joints, and among them, the 7-axis joint operates the forceps. At this time, the forceps joint (#7 axis) can only operate open and close functions, while the link is bent and rotatable, regardless of position change. This phenomenon can be analyzed by Forward Kinematics. Also, when the DOF rotates, the passing wires become twisted, and the wire is generated through length change and coupling phenomenon. The maximum rotation angle of DOF is 90° and the rotating passing wire is wound by the rotation of the wire pulley. If the DOF is rotated to the full range of 120°, the second DOF will be rotated to 90°, and at this time, the coupling phenomenon caused by the first DOF rotation can be eliminated. The length change and the robot joint angle change related to the motor drive, based on the surgical robot control using the wire-driven method, are correlated, and the values for the position and direction of the end effector of the robot can be obtained through a forward kinematic analysis. The coupling problem occurring in the wire connecting the robot driving part can be solved through a kinematic analysis. Therefore, it was possible to test the position of the slave robot and the performance of the surgical forceps movement using the master system.
Keywords: 7-axis joint; surgical robot; wire-driven method; coupling effect; forward kinematics (search for similar items in EconPapers)
JEL-codes: C (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/2227-7390/10/10/1698/pdf (application/pdf)
https://www.mdpi.com/2227-7390/10/10/1698/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jmathe:v:10:y:2022:i:10:p:1698-:d:816480
Access Statistics for this article
Mathematics is currently edited by Ms. Emma He
More articles in Mathematics from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().