An Approach to Assessing Spatial Coherence of Current and Voltage Signals in Electrical Networks
Pavel Ilyushin,
Aleksandr Kulikov,
Konstantin Suslov and
Sergey Filippov
Additional contact information
Pavel Ilyushin: Energy Research Institute of the Russian Academy of Sciences, 117186 Moscow, Russia
Aleksandr Kulikov: Department of Electroenergetics, Power Supply and Power Electronics, Nizhny Novgorod State Technical University, n.a. R.E. Alekseev, 603950 Nizhny Novgorod, Russia
Konstantin Suslov: Department of Power Supply and Electrical Engineering, Irkutsk National Research Technical University, 664074 Irkutsk, Russia
Sergey Filippov: Energy Research Institute of the Russian Academy of Sciences, 117186 Moscow, Russia
Mathematics, 2022, vol. 10, issue 10, 1-15
Abstract:
In the context of energy industry decentralization, electrical networks encounter deviations of power quality indices (PQI), including violations of the sinusoidality of current and voltage signals, which increase errors in the joint digital processing of spatially separated signals in digital devices. This paper addresses specific features of using the concept of spatial coherence in the measurement and digital processing of current and voltage signals. Methods for assessing the coherence of current and voltage signals during synchronized measurements are considered for the case of PQI deviation. The example of a double-ended transmission line fault location (hereafter, DTLFL) demonstrates that the lower the cross-correlation coefficient, the higher the error and the lower the accuracy of calculating the distance to the fault site. The nature of the influence of spatial coherence violations on errors in DTLFL depends on the expression used to calculate the distance to the fault point. The application of a normalized cross-correlation coefficient for finding errors in the digital processing of current and voltage signals, in the case of spatial coherence violation, was substantiated. The influence of interharmonics and noise on errors in DTLFL, in the case of violations of spatial coherence of signals, was investigated. The magnitude of distortions and error in estimating the current and voltage amplitude depends on the ratio between the amplitudes and phases of the fundamental and distorting interharmonics. Filtration of the original and decimated signals based on the discrete Fourier transform eliminates the noise components of the power frequency harmonics.
Keywords: spatial coherence; normalized cross-correlation coefficient; power quality indices; synchronized measurements; double-ended transmission line fault location (search for similar items in EconPapers)
JEL-codes: C (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/2227-7390/10/10/1768/pdf (application/pdf)
https://www.mdpi.com/2227-7390/10/10/1768/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jmathe:v:10:y:2022:i:10:p:1768-:d:821212
Access Statistics for this article
Mathematics is currently edited by Ms. Emma He
More articles in Mathematics from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().