EconPapers    
Economics at your fingertips  
 

Using Matlab/Simulink Software Package to Investigate Fault Behaviors in HVDC System

Olumoroti Ikotun, Ephraim Bonah Agyekum, Emad M. Ahmed () and Salah Kamel
Additional contact information
Olumoroti Ikotun: Department of Electrical and Electronics Engineering, Federal University Oye-Ekiti, P.M.B. 373, Km 3 Oye-Afao Road, Oye-Ekiti 370112, Ekiti State, Nigeria
Ephraim Bonah Agyekum: Department of Nuclear and Renewable Energy, Ural Federal University Named after the First President of Russia Boris Yeltsin, 19 Mira Street, 620002 Ekaterinburg, Russia
Emad M. Ahmed: Department of Electrical Engineering, College of Engineering, Jouf University, Sakaka 72388, Saudi Arabia
Salah Kamel: Department of Electrical Engineering, Faculty of Engineering, Aswan University, Aswan 81542, Egypt

Mathematics, 2022, vol. 10, issue 16, 1-17

Abstract: Existing studies show that several performance issues will arise in the HVDC link during the three phase-to-ground fault at the side of the inverter and that the DC voltage will oscillate around zero and will not affect the rectifier of the AC system though the inverter of the AC system, and the AC voltages will become zero and the AC currents will show high amplitude as well as minor disturbances. It has also been argued that when the fault is applied on a single-phase to ground fault at the inverter side on the AC side, the voltage will decrease. In this paper, we focus on single line-to-ground fault, double line-to-ground fault, and three phase-to-ground fault at the inverter of the AC system and their behavior on the DC link as well as on the AC system of the rectifier with detailed simulations. A high voltage direct current (HVDC) Monopolar system is modeled using a Matlab/Simulink software package for the research. The results show that during the three phase-to-ground fault at the AC system of the inverter, the DC voltage will increase with a bogus waveform and the currents of the AC system at the rectifier will collapse to zero.At the double phase-to-ground fault level, the DC voltage will experience an increase in waveform while the currents of the AC system of the rectifier will experience different disturbances. At the single phase-to-ground fault level, the DC voltage will remain stable and the rectifier side of the AC system will also experience a stable state for both currents and voltages.

Keywords: mono-polar HVDC system; inverter; rectifier; fault analysis; Matlab/Simulink (search for similar items in EconPapers)
JEL-codes: C (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/2227-7390/10/16/3014/pdf (application/pdf)
https://www.mdpi.com/2227-7390/10/16/3014/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jmathe:v:10:y:2022:i:16:p:3014-:d:893899

Access Statistics for this article

Mathematics is currently edited by Ms. Emma He

More articles in Mathematics from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jmathe:v:10:y:2022:i:16:p:3014-:d:893899