EconPapers    
Economics at your fingertips  
 

Methods for Mathematical Analysis of Simulated and Real Fractal Processes with Application in Cardiology

Evgeniya Gospodinova (), Penio Lebamovski, Galya Georgieva-Tsaneva, Galina Bogdanova and Diana Dimitrova
Additional contact information
Evgeniya Gospodinova: Institute of Robotics, Bulgarian Academy of Science, 1113 Sofia, Bulgaria
Penio Lebamovski: Institute of Robotics, Bulgarian Academy of Science, 1113 Sofia, Bulgaria
Galya Georgieva-Tsaneva: Institute of Robotics, Bulgarian Academy of Science, 1113 Sofia, Bulgaria
Galina Bogdanova: Institute of Mathematics and Informatics, Bulgarian Academy of Science, 1113 Sofia, Bulgaria
Diana Dimitrova: Faculty of Public Health, Medical University “Prof. Dr. P. Stoyanov”-Varna, 9000 Varna, Bulgaria

Mathematics, 2022, vol. 10, issue 19, 1-16

Abstract: In the article, a comparative analysis is performed regarding the accuracy parameter in determining the degree of self-similarity of fractal processes between the following methods: Variance-Time plot, Rescaled Range (R/S), Wavelet-based, Detrended Fluctuation Analysis (DFA) and Multifractal Detrended Fluctuation Analysis (MFDFA). To evaluate the methods, fractal processes based of Fractional Gaussian Noise were simulated and the dependence between the length of the simulated process and the degree of self-similarity was investigated by calculating the Hurst exponent (H > 0.5). It was found that the Wavelet-based, DFA and MFDFA methods, with a process length greater than 2 14 points, have a relative error of the Hurst exponent is less than 1%. A methodology for the Wavelet-based method related to determining the size of the scale and the wavelet algorithm was proposed, and it was investigated in terms of the exact determination of the Hurst exponent of two algorithms: Haar and Daubechies with different number of coefficients and different values of the scale. Based on the analysis, it was determined that the Daubechies algorithm with 10 coefficients and scale (i = 2, j = 10) has a relative error of less than 0.5%. The three most accurate methods are applied to the study of real cardiac signals of two groups of people: healthy and unhealthy (arrhythmia) subjects. The results of the statistical analysis, using the t-test, show that the proposed methods can distinguish the two studied groups and can be used for diagnostic purposes.

Keywords: fractal process; Hurst exponent; multifractal process; RR time series (search for similar items in EconPapers)
JEL-codes: C (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/2227-7390/10/19/3427/pdf (application/pdf)
https://www.mdpi.com/2227-7390/10/19/3427/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jmathe:v:10:y:2022:i:19:p:3427-:d:920684

Access Statistics for this article

Mathematics is currently edited by Ms. Emma He

More articles in Mathematics from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jmathe:v:10:y:2022:i:19:p:3427-:d:920684