EconPapers    
Economics at your fingertips  
 

Modified Whiteside’s Line-Based Transepicondylar Axis for Imageless Total Knee Arthroplasty

Muhammad Sohail, Jaehyun Park, Jun Young Kim, Heung Soo Kim () and Jaehun Lee ()
Additional contact information
Muhammad Sohail: Department of Mechanical, Robotics and Energy Engineering, Dongguk University-Seoul, Seoul 04620, Korea
Jaehyun Park: Department of Mechanical, Robotics and Energy Engineering, Dongguk University-Seoul, Seoul 04620, Korea
Jun Young Kim: Department of Mechanical, Robotics and Energy Engineering, Dongguk University-Seoul, Seoul 04620, Korea
Heung Soo Kim: Department of Mechanical, Robotics and Energy Engineering, Dongguk University-Seoul, Seoul 04620, Korea
Jaehun Lee: Department of Mechanical, Robotics and Energy Engineering, Dongguk University-Seoul, Seoul 04620, Korea

Mathematics, 2022, vol. 10, issue 19, 1-17

Abstract: One of the aims of successful total knee arthroplasty (TKA) is to restore the natural range of motion of the infected joint. The operated leg motion highly depends on the coordinate systems that have been used to prepare the bone surfaces for an implant. Assigning a perfect coordinate system to the knee joint is a considerable challenge. Various commercially available knee arthroplasty devices use different methods to assign the coordinate system at the distal femur. Transepicondylar axis (TEA) and Whiteside’s line are commonly used anatomical axes for defining a femoral coordinate system (FCS). However, choosing a perfect TEA for FCS is trickier, even for experienced surgeons, and a small error in marking Whiteside’s line leads to a misaligned knee joint. This work proposes a modified Whiteside’s line method for the selection of TEA. The Whiteside’s line, along with the knee center and femur head center, define two independent central planes. Multiple prominent points on the lateral and medial sides of epicondyles are marked. Based on the lengths of perpendicular distances between the multiple points and central planes, the most prominent epicondyle points are chosen to define an optimal TEA. Compared to conventional techniques, the modified Whiteside’s line defines a repeatable TEA

Keywords: imageless navigator; knee alignment device; total knee arthroplasty; repeatable transepicondylar axis; femoral coordinate system; modified Whiteside’s line (search for similar items in EconPapers)
JEL-codes: C (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/2227-7390/10/19/3670/pdf (application/pdf)
https://www.mdpi.com/2227-7390/10/19/3670/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jmathe:v:10:y:2022:i:19:p:3670-:d:935341

Access Statistics for this article

Mathematics is currently edited by Ms. Emma He

More articles in Mathematics from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jmathe:v:10:y:2022:i:19:p:3670-:d:935341