Sizing and Design of a PV-Wind-Fuel Cell Storage System Integrated into a Grid Considering the Uncertainty of Load Demand Using the Marine Predators Algorithm
Fayza S. Mahmoud,
Ashraf M. Abdelhamid (),
Ameena Al Sumaiti (),
Abou-Hashema M. El-Sayed and
Ahmed A. Zaki Diab ()
Additional contact information
Fayza S. Mahmoud: Electrical Engineering Department, Faculty of Engineering, Minia University, Minia 61111, Egypt
Ashraf M. Abdelhamid: Communications and Electronics Engineering Department, College of Engineering, Umm Al-Qura University, Al-Lith Branch, Makkah 24382, Saudi Arabia
Ameena Al Sumaiti: Advanced Power and Energy Center, Electrical Engineering and Computer Science, Khalifa University, Abu Dhabi 127788, United Arab Emirates
Abou-Hashema M. El-Sayed: Electrical Engineering Department, Faculty of Engineering, Minia University, Minia 61111, Egypt
Ahmed A. Zaki Diab: Electrical Engineering Department, Faculty of Engineering, Minia University, Minia 61111, Egypt
Mathematics, 2022, vol. 10, issue 19, 1-26
Abstract:
In this paper, the utility grid is integrated with hybrid photovoltaic (PV)/wind/fuel cells to overcome the unavailability of the grid and the single implementation of renewable energy. The main purpose of this study is smart management of hydrogen storage tanks and power exchange between the hybrid renewable energy and the grid to minimize the total cost of the hybrid system and load uncertainties. PV and wind act as the main renewable energy sources, whereas fuel cells act as auxiliary sources designed to compensate for power variations and to ensure continuous power flow to the load. The grid is considered a backup system that works when hybrid renewable energy and fuel cells are unavailable. In this study, the optimal size of the components of the hybrid energy system is introduced using two methods: the marine predators’ algorithm (MPA) and the seagull optimization algorithm (SOA). The optimal sizing problem is also run accounting for the uncertainty in load demand. The results obtained from the proposed optimization are given with and without uncertainty in load demand. The simulation results of the hybrid system without uncertainty demonstrate the superiority of the MPA compared with SOA. However, in the case of load uncertainty, the simulation results (the uncertainty) are given using the MPA optimization technique with +5%, +10%, and +15% uncertainty in load, which showed that the net present cost and purchase energy are increased with uncertainty.
Keywords: energy system; PV; wind; fuel cell; optimization; hybrid renewable energy (search for similar items in EconPapers)
JEL-codes: C (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/2227-7390/10/19/3708/pdf (application/pdf)
https://www.mdpi.com/2227-7390/10/19/3708/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jmathe:v:10:y:2022:i:19:p:3708-:d:938078
Access Statistics for this article
Mathematics is currently edited by Ms. Emma He
More articles in Mathematics from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().