Mathematics, 2023, vol. 11, issue 12, 1-19

Abstract: When tunable diode laser absorption spectroscopy is used to measure the concentration of gas, the second harmonic signal of demodulation is changed due to the influence of temperature change, and the error in concentration measurement is great. In order to solve the problem of large errors in atmospheric quality monitoring equipment due to the change in gas temperature, this paper, based on the tunable semiconductor laser absorption spectroscopy (TDLAS) theory, measured methane gas with 1000 ppm standard gas as the target and selected the central absorption wavelength of 1650 nm. The influence of temperature change on gas injection and the laser absorption spectrometer is studied. A temperature compensation algorithm based on an empirical formula is designed. Firstly, by analyzing the variable temperature test data of the detection module, it is proposed to divide the influence factors of temperature into two parts and study the influence of injection gas temperature and detector temperature, respectively. Secondly, the temperature compensation is carried out by polynomial fitting the concentration inversion results. Finally, according to the compensation effect, a scheme was proposed to compensate the measured gas by applying a constant temperature treatment to the detector at 313 K. After compensation, the average error of the system measurement is reduced from 8.4% to 1.08% when the gas temperature changes from 233 K to 343 K, which effectively reduces the deviation of the measured value caused by the abrupt temperature change. It further improves the accuracy and reliability of measuring gas concentration when gas inspection equipment is working outdoors and has strong practicability.

Keywords: tunable diode laser absorption spectroscopy (TDLAS); methane concentration; second harmonic; temperature compensation (search for similar items in EconPapers)
JEL-codes: C (search for similar items in EconPapers)
Date: 2023
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/2227-7390/11/12/2656/pdf (application/pdf)
https://www.mdpi.com/2227-7390/11/12/2656/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jmathe:v:11:y:2023:i:12:p:2656-:d:1168438

Access Statistics for this article

Mathematics is currently edited by Ms. Emma He

More articles in Mathematics from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jmathe:v:11:y:2023:i:12:p:2656-:d:1168438