EconPapers    
Economics at your fingertips  
 

Chebyshev Interpolation Using Almost Equally Spaced Points and Applications in Emission Tomography

Vangelis Marinakis, Athanassios S. Fokas, George A. Kastis and Nicholas E. Protonotarios ()
Additional contact information
Vangelis Marinakis: Department of Civil Engineering, University of the Peloponnese, 26334 Patras, Greece
Athanassios S. Fokas: Department of Applied Mathematics and Theoretical Physics, University of Cambridge, Cambridge CB3 0WA, UK
George A. Kastis: Mathematics Research Center, Academy of Athens, 11527 Athens, Greece
Nicholas E. Protonotarios: Mathematics Research Center, Academy of Athens, 11527 Athens, Greece

Mathematics, 2023, vol. 11, issue 23, 1-14

Abstract: Since their introduction, Chebyshev polynomials of the first kind have been extensively investigated, especially in the context of approximation and interpolation. Although standard interpolation methods usually employ equally spaced points, this is not the case in Chebyshev interpolation. Instead of equally spaced points along a line, Chebyshev interpolation involves the roots of Chebyshev polynomials, known as Chebyshev nodes, corresponding to equally spaced points along the unit semicircle. By reviewing prior research on the applications of Chebyshev interpolation, it becomes apparent that this interpolation is rather impractical for medical imaging. Especially in clinical positron emission tomography (PET) and in single-photon emission computerized tomography (SPECT), the so-called sinogram is always calculated at equally spaced points, since the detectors are almost always uniformly distributed. We have been able to overcome this difficulty as follows. Suppose that the function to be interpolated has compact support and is known at q equally spaced points in − 1 , 1 . We extend the domain to − a , a , a > 1 , and select a sufficiently large value of a , such that exactly q Chebyshev nodes are included in − 1 , 1 , which are almost equally spaced. This construction provides a generalization of the concept of standard Chebyshev interpolation to almost equally spaced points. Our preliminary results indicate that our modification of the Chebyshev method provides comparable, or, in several cases including Runge’s phenomenon, superior interpolation over the standard Chebyshev interpolation. In terms of the L ∞ norm of the interpolation error, a decrease of up to 75% was observed. Furthermore, our approach opens the way for using Chebyshev polynomials in the solution of the inverse problems arising in PET and SPECT image reconstruction.

Keywords: Chebyshev polynomials; Chebyshev nodes; polynomial interpolation; medical image reconstruction; emission tomography; PET; SPECT (search for similar items in EconPapers)
JEL-codes: C (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/2227-7390/11/23/4757/pdf (application/pdf)
https://www.mdpi.com/2227-7390/11/23/4757/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jmathe:v:11:y:2023:i:23:p:4757-:d:1287393

Access Statistics for this article

Mathematics is currently edited by Ms. Emma He

More articles in Mathematics from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jmathe:v:11:y:2023:i:23:p:4757-:d:1287393