Indoor/Outdoor Relationships of Airborne Particles under Controlled Pressure Difference across the Building Envelope in Korean Multifamily Apartments
Dong Hee Choi and
Dong Hwa Kang
Additional contact information
Dong Hee Choi: Department of Architectural Engineering, College of Engineering, Kyungil University, Kyungsan 38428, Korea
Dong Hwa Kang: Department of Architectural Engineering, College of Urban Sciences, University of Seoul, Seoul 02504, Korea
Sustainability, 2018, vol. 10, issue 11, 1-14
Abstract:
This study investigates indoor/outdoor relationships of airborne particles under controlled pressure difference across the building envelope in Korean multifamily apartments. On-site field experiments on 14 apartment housing units located in urban areas in Korea are conducted to measure the indoor/outdoor ratios of number concentrations of size-resolved particles (0.3–0.5, 0.5–1.0, 1.0–3.0, 3.0–5.0, 5.0–10.0, >10.0 μm). To set identical pressure difference conditions across the envelope of each housing unit for better comparison of I/O ratio results, and to examine the effect of pressure difference on the I/O relations, indoor–outdoor pressure difference was controlled at 10, 30, and 50 Pa using a blower door depressurization procedure. Simultaneously, the air leakage characteristics of housing units are measured using the typical blower door pressurization-depressurization test method to correlate air leakage data and I/O ratios. As expected, moderately airtight housing units (ACH 50 ≤ 4.4) show lower I/O ratios than average leaky housing units (ACH 50 > 4.4); still, the averaged I/O ratios of finer sized particles (0.3–0.5, 0.5–1.0, and 1.0–3.0 μm) in the moderately airtight housing units were 0.75, 0.59, and 0.61 at an I-O pressure difference of 50 Pa, and 0.62, 0.51, and 0.49 at 10 Pa. The study indicates that indoor residents in moderately airtight Korean multifamily housing units with relatively small envelope area can still be exposed to high concentrations of outdoor originated fine particles.
Keywords: particle infiltration; I/O ratio; urban apartments; air leakage; I-O pressure difference; blower door test (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (4)
Downloads: (external link)
https://www.mdpi.com/2071-1050/10/11/4074/pdf (application/pdf)
https://www.mdpi.com/2071-1050/10/11/4074/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:10:y:2018:i:11:p:4074-:d:181041
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().