Evaluating the Fires and Oxygen Deficiency Risks Caused by Stored Agricultural Waste
Naoharu Murasawa,
Hiroshi Koseki,
Yusaku Iwata and
Takabumi Sakamoto
Additional contact information
Naoharu Murasawa: Faculty of Risk and Crisis Management, Chiba Institute of Science, 3 Shiomi-Cho, Choshi, Chiba 288-0025, Japan
Hiroshi Koseki: National Research Institute of Fire and Disaster, 4-35-3, Jindaiji-Higashimachi, Chofu, Tokyo 182-8508, Japan
Yusaku Iwata: National Research Institute of Fire and Disaster, 4-35-3, Jindaiji-Higashimachi, Chofu, Tokyo 182-8508, Japan
Takabumi Sakamoto: College of Risk and Crisis Management, Kurashiki University of Science and the Arts, 2640 Nishinoura, Turajimacho, Kuraashiki, Okayama 712-8505, Japan
Sustainability, 2018, vol. 10, issue 4, 1-16
Abstract:
In the Japanese agricultural industry, efforts are being made to recycle waste produced in order to use resources more efficiently. However, in some cases, when stored for long periods of time these materials generate heat through fermentation, which can eventually result in spontaneous ignition or oxygen deficiency in storage areas, resulting in the deaths of workers. In this study, we conducted a series of experiments on several types of agricultural waste (organic waste generated by agricultural production activities in Japan) frequently stored for recycling, using combinations of various thermal- and gas-analysers, in order to identify the risk factors related to spontaneous ignition and oxygen deficiency accidents. The aim of this research was to understand the circumstances leading to spontaneous ignition and oxygen deficiency accidents in storage facilities and to recommend safety measures to prevent such occurrences. Our results suggest that fermentation is likely responsible for the generation of heat and production of carbon dioxide at temperatures up to approximately 50 °C, where microbial activity diminishes. At temperatures beyond 50 °C, a transition into heat generation by the oxidation of fatty acid esters occurs. Additionally, when the barrier of heat absorption is overcome at around 100 °C due to the evaporation of water, there is a transition to thermal cracking that could lead to fire. Accidents due to oxygen deficiency may occur when a storage facility is well sealed and the amount of oxygen circulation is minimal. However, when the amount of oxygen is sufficient; the substance is stored in large deposits; and the facility is well insulated, fermentation can cause the temperature to increase. Therefore, it is desirable to periodically measure the temperature of stored materials and monitor the generated gases.
Keywords: agricultural waste; fermentation; thermal and gas analysis; spontaneous ignition; oxygen deficiency (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/2071-1050/10/4/1116/pdf (application/pdf)
https://www.mdpi.com/2071-1050/10/4/1116/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:10:y:2018:i:4:p:1116-:d:140133
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().