Empirical Study of How Traffic Intensity Detector Parameters Influence Dynamic Street Lighting Energy Consumption: A Case Study in Krakow, Poland
Igor Wojnicki and
Leszek Kotulski
Additional contact information
Igor Wojnicki: Department of Applied Computer Science, AGH University of Science and Technology, Al.Mickiewicza 30, 30-059 Kraków, Poland
Leszek Kotulski: Department of Applied Computer Science, AGH University of Science and Technology, Al.Mickiewicza 30, 30-059 Kraków, Poland
Sustainability, 2018, vol. 10, issue 4, 1-16
Abstract:
The deployment of dynamic street lighting, which adjusts lighting levels to fulfill particular needs, leads to energy savings. These savings contribute to the overall lighting infrastructure maintenance cost. Yet another contribution is the cost of traffic intensity data. The data is read directly from sensor systems or intelligent transportation systems (ITSs). The more frequent the readings are, the more costly they become, because of hardware capabilities, data transfer and software license costs, among others. The paper investigates a relationship between the frequency of readings, in particular the averaging window size and step, and achieved energy savings. It is based on a simulation, taking into account a representative part of a city and traffic intensity data, which span over a period of one year. While the energy consumption reduction is simulated, all data, including each luminaire power setting, induction loop locations and street characteristics, come from a representative sample of the city of Krakow, Poland. Controlling the power settings complies with the lighting standard CEN/TR 13201. Analysis of the outcomes indicates that the shorter the window size or step are, the more energy saving that is available. In particular, for the previous standard CEN/TR 13201 2004, having the window size and step at 15 min results in 26.75% of energy saving, while reducing these values to 6 min provides 27%. Savings are more profound for the current standard (CEN/TR 13201 2014), assuming a 15 min size and step results in 47.43%, while having a 6 min size and step provides 47.69%. The results can serve as a guideline for identifying the economic viability of dynamic lighting control systems. Additionally, it can be observed that the current lighting standard provides far greater potential for dynamic control then the previous standard.
Keywords: dynamic control; graph model; sensor readings; street lighting; traffic intensity data (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (11)
Downloads: (external link)
https://www.mdpi.com/2071-1050/10/4/1221/pdf (application/pdf)
https://www.mdpi.com/2071-1050/10/4/1221/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:10:y:2018:i:4:p:1221-:d:141514
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().