EconPapers    
Economics at your fingertips  
 

Transforming Data Centers in Active Thermal Energy Players in Nearby Neighborhoods

Marcel Antal, Tudor Cioara, Ionut Anghel, Claudia Pop and Ioan Salomie
Additional contact information
Marcel Antal: Computer Science Department, Technical University of Cluj-Napoca, Memorandumului 28, 400114 Cluj-Napoca, Romania
Tudor Cioara: Computer Science Department, Technical University of Cluj-Napoca, Memorandumului 28, 400114 Cluj-Napoca, Romania
Ionut Anghel: Computer Science Department, Technical University of Cluj-Napoca, Memorandumului 28, 400114 Cluj-Napoca, Romania
Claudia Pop: Computer Science Department, Technical University of Cluj-Napoca, Memorandumului 28, 400114 Cluj-Napoca, Romania
Ioan Salomie: Computer Science Department, Technical University of Cluj-Napoca, Memorandumului 28, 400114 Cluj-Napoca, Romania

Sustainability, 2018, vol. 10, issue 4, 1-20

Abstract: In this paper, we see the Data Centers (DCs) as producers of waste heat integrated with smart energy infrastructures, heat which can be re-used for nearby neighborhoods. We provide a model of the thermo-electric processes within DCs equipped with heat reuse technology, allowing them to adapt their thermal response profile to meet various levels of hot water demand. On top of the model, we have implemented computational fluid dynamics-based simulations to determine the cooling system operational parameters settings, which allow the heat to build up without endangering the servers’ safety operation as well as the distribution of the workload on the servers to avoid hot spots. This will allow for setting higher temperature set points for short periods of time and using pre-cooling and post-cooling as flexibility mechanisms for DC thermal profile adaptation. To reduce the computational time complexity, we have used neural networks, which are trained using the simulation results. Experiments have been conducted considering a small operational DC featuring a server room of 24 square meters and 60 servers organized in four racks. The results show the DCs’ potential to meet different levels of thermal energy demand by re-using their waste heat in nearby neighborhoods.

Keywords: data centers; waste heat re-use; thermal energy flexibility; thermal profile adaptation; neural networks; computation fluid dynamics (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (7)

Downloads: (external link)
https://www.mdpi.com/2071-1050/10/4/939/pdf (application/pdf)
https://www.mdpi.com/2071-1050/10/4/939/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:10:y:2018:i:4:p:939-:d:137737

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:10:y:2018:i:4:p:939-:d:137737