EconPapers    
Economics at your fingertips  
 

An Efficient Burst Detection and Isolation Monitoring System for Water Distribution Networks Using Multivariate Statistical Techniques

KiJeon Nam, Pouya Ifaei, Sungku Heo, Gahee Rhee, Seungchul Lee and ChangKyoo Yoo
Additional contact information
KiJeon Nam: Department of Environmental Science and Engineering, College of Engineering, Kyung Hee University, Seocheon-dong 1, Giheung-gu, Yongin-si, Gyeonggi-do 446-701, Korea
Pouya Ifaei: Department of Environmental Science and Engineering, College of Engineering, Kyung Hee University, Seocheon-dong 1, Giheung-gu, Yongin-si, Gyeonggi-do 446-701, Korea
Sungku Heo: Department of Environmental Science and Engineering, College of Engineering, Kyung Hee University, Seocheon-dong 1, Giheung-gu, Yongin-si, Gyeonggi-do 446-701, Korea
Gahee Rhee: Department of Environmental Science and Engineering, College of Engineering, Kyung Hee University, Seocheon-dong 1, Giheung-gu, Yongin-si, Gyeonggi-do 446-701, Korea
Seungchul Lee: Technology Development Center, Samsung engineering, Woncheon-dong, Yeongtong-gu, Suwon-si, Gyeonggi-do 446-701, Korea
ChangKyoo Yoo: Department of Environmental Science and Engineering, College of Engineering, Kyung Hee University, Seocheon-dong 1, Giheung-gu, Yongin-si, Gyeonggi-do 446-701, Korea

Sustainability, 2019, vol. 11, issue 10, 1-17

Abstract: Detection and isolation of burst locations in water distribution networks (WDN) are challenging problems in urban management because burst events cause considerable economic, social, and environmental losses. In the present study, a novel monitoring and sensor placement approach is proposed for rapid and robust burst detection. Accordingly, a hybrid principal component analysis (PCA) and standardized exponential weighted moving average (EWMA) system is proposed for WDN monitoring and management. In addition, the optimal sensor configuration is obtained using PCA, k -means clustering, and a sensitivity analysis considering the diurnal patterns and the noises of pressure and flowrate data in the WDN. The proposed system is applied to a branched WDN, and the results are compared to those obtained with conventional monitoring systems. The results show that the proposed system detected the burst occurrence regardless of noise size with a detection rate of 93%. Compared to conventional systems, the isolation ratio improved by 10%, indicating that the bursts were isolated more accurately. In addition, the corresponding sensor configuration was 40% less expensive than the conventional systems.

Keywords: burst isolation; burst monitoring; optimal sensor location; pipe burst; water distribution network (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2019
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (3)

Downloads: (external link)
https://www.mdpi.com/2071-1050/11/10/2970/pdf (application/pdf)
https://www.mdpi.com/2071-1050/11/10/2970/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:11:y:2019:i:10:p:2970-:d:234080

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:11:y:2019:i:10:p:2970-:d:234080