EconPapers    
Economics at your fingertips  
 

Pressurization Ventilation Technique for Controlling Gas Leakage and Dispersion at Backfilled Working Faces in Large-Opening Underground Mines: CFD Analysis and Experimental Tests

Nguyen Van-Duc, Won-Ho Heo, Rocky Kubuya and Chang-Woo Lee
Additional contact information
Nguyen Van-Duc: Department of Energy and Mineral Resources, College of Engineering, Dong-A University, Saha-gu, Busan 49315, Korea
Won-Ho Heo: Mining Tech Co., Ltd, Saha-gu, Busan 49315, Korea
Rocky Kubuya: Department of Energy and Mineral Resources, College of Engineering, Dong-A University, Saha-gu, Busan 49315, Korea
Chang-Woo Lee: Department of Energy and Mineral Resources, College of Engineering, Dong-A University, Saha-gu, Busan 49315, Korea

Sustainability, 2019, vol. 11, issue 12, 1-18

Abstract: Pressurization ventilation techniques, originally designed to control building fires, have never been applied to the mines. The working face, backfilled with fly-ash-based materials, is likely to be contaminated during, and even after, the curing period of the backfill materials. Gases such as NH 3 and CO 2 may leak out prolongedly from the backfilled sites. Proper ventilation schemes should be implemented to control toxic gas leakage and thus minimize the workers’ exposure. This study aims at evaluating the applicability of a pressurization ventilation scheme at backfilled working faces in large-opening limestone mines. To pressurize the working face, two different fans (15 kW and 37 kW) were developed and two ventilation scenarios were tested. Computational Fluid Dynamics (CFD) analysis was also carried out for comparison purposes. There is no established standard for differential pressure between the inside and outside of working faces to prevent gas leakage at mines. However, taking the differential pressure of 50 Pa in British standards for controlling building fires (where a relatively stronger dissipation force than the gas leakage of a mining face occurs), the pressure differential created by two blowing fans seems to be sufficient to control the gas leakage and dispersion within the work space.

Keywords: pressurization system; ventilation fan; differential pressure; gas leakage; backfilled area (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2019
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/2071-1050/11/12/3313/pdf (application/pdf)
https://www.mdpi.com/2071-1050/11/12/3313/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:11:y:2019:i:12:p:3313-:d:240132

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:11:y:2019:i:12:p:3313-:d:240132