Carbon Dioxide Emissions during Air, Ground, or Groundwater Heat Pump Performance in Białystok
Andrzej Gajewski,
Katarzyna Gładyszewska-Fiedoruk and
Dorota Anna Krawczyk
Additional contact information
Andrzej Gajewski: Department of HVAC Engineering, Faculty of Civil Engineering and Environmental Engineering, Bialystok University of Technology, 15-351 Bialystok, Poland
Katarzyna Gładyszewska-Fiedoruk: Department of HVAC Engineering, Faculty of Civil Engineering and Environmental Engineering, Bialystok University of Technology, 15-351 Bialystok, Poland
Dorota Anna Krawczyk: Department of HVAC Engineering, Faculty of Civil Engineering and Environmental Engineering, Bialystok University of Technology, 15-351 Bialystok, Poland
Sustainability, 2019, vol. 11, issue 18, 1-16
Abstract:
The increasing global temperature has induced many states to limit carbon dioxide emissions. The European Union (EU) promotes replacing boilers with heat pumps. However, in countries where electricity is mainly supplied through fossil fuel combustion, condensing gas boilers may prove to be more ecological heat generators. Although this problem was investigated in a particular situation, an algorithm can be applied elsewhere. The running expenditures for the following different heat generators that are available in a location were estimated: water heat pump, brine heat pump, air heat pump, condensing gas boiler, condensing oil boiler, district heat network, and electrical grid. Furthermore, carbon dioxide emissions from local and distant sources were evaluated. The computations were based on hourly averaged external temperature measurements, which were performed by the Institute of Meteorology and Water Management—National Research Institute (IMGW-PIB) in a weather station in Białystok (Poland) for a ten-year period. Compared with a condensing gas boiler system, the air-to-water heat pump has higher operating costs and higher CO 2 emissions. The brine heat pump (closed-loop ground-source heat pump) has lower operating costs, but higher CO 2 emissions than the gas boiler system. The water heat pump (groundwater source heat pump) has the lowest operating costs and CO 2 emissions of all the systems studied in this paper.
Keywords: air heat pump; brine heat pump; water heat pump; seasonal coefficient of performance; carbon dioxide emissions (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2019
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (6)
Downloads: (external link)
https://www.mdpi.com/2071-1050/11/18/5087/pdf (application/pdf)
https://www.mdpi.com/2071-1050/11/18/5087/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:11:y:2019:i:18:p:5087-:d:268087
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().