EconPapers    
Economics at your fingertips  
 

Assessment of the Equivalence of Low-Cost Sensors with the Reference Method in Measuring PM 10 Concentration Using Selected Correction Functions

Tomasz Owczarek, Mariusz Rogulski and Piotr O. Czechowski
Additional contact information
Tomasz Owczarek: Faculty of Entrepreneurship and Quality Science, Gdynia Maritime University, Morska 81-87, 81-225 Gdynia, Poland
Mariusz Rogulski: Hydro and Environmental Engineering, Faculty of Building Services, Warsaw University of Technology, Nowowiejska 20, 00-653 Warsaw, Poland
Piotr O. Czechowski: Faculty of Entrepreneurship and Quality Science, Gdynia Maritime University, Morska 81-87, 81-225 Gdynia, Poland

Sustainability, 2020, vol. 12, issue 13, 1-17

Abstract: The aim of the work is to demonstrate the possibility of building models to correct the results of measurements of particulate matter PM 10 concentrations obtained using low-cost devices. Such devices apply the optical method to values comparable with those obtained using the reference gravimetric method. An additional goal is to show that the results corrected in this way can be used to carry out the procedure for testing equivalence of these methods. The study used generalized regression models (GRMs) to construct corrective functions. The constructed models were assessed using the coefficients of determination and the methodology of calculating the measurement uncertainty of the device. Measurement data from the two tested devices and the reference method were used to estimate model parameters. The measurement data were collected on a daily basis from 1 February to 30 June 2018 in Nowy Sącz. Regression allowed building multiple models with various functional forms and very promising statistical properties as well as good ability to describe the variability of reference measurements. These models also had very low values of measurement uncertainty. Of all the models constructed, a linear model using the original PM 10 concentrations from the tested devices, air humidity, and wind speed was chosen as the most accurate and simplest model. Apart from the coefficient of determination, expanded relative uncertainty served as the measure of quality of the obtained model. Its small value, much lower than 25%, indicates that after correcting the results it is possible to carry out the equivalence testing procedure for the low-cost devices and confirm the equivalence of the tested method with the reference method.

Keywords: air pollution; particulate matter; low cost meters; PM 10 concentrations; equivalence of measurement methods; uncertainty of measurement (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2020
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/2071-1050/12/13/5368/pdf (application/pdf)
https://www.mdpi.com/2071-1050/12/13/5368/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:12:y:2020:i:13:p:5368-:d:379620

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-04-18
Handle: RePEc:gam:jsusta:v:12:y:2020:i:13:p:5368-:d:379620