Influence of Indoor Climate on Employees in Office Buildings—A Case Study
Peter Kapalo,
Silvia Vilčeková,
Ľudmila Mečiarová,
Florin Domnita and
Mariusz Adamski
Additional contact information
Peter Kapalo: Institute of Architectural Engineering, Faculty of Civil Engineering, Technical University of Košice, Vysokoškolská 4, 04200 Košice, Slovakia
Silvia Vilčeková: Institute of Environmental Engineering, Faculty of Civil Engineering, Technical University of Košice, Vysokoškolská 4, 04200 Košice, Slovakia
Ľudmila Mečiarová: Institute of Environmental Engineering, Faculty of Civil Engineering, Technical University of Košice, Vysokoškolská 4, 04200 Košice, Slovakia
Florin Domnita: Department of Building Services Engineering, Technical University of Cluj-Napoca, B-dul 21 December 1989, nr. 128-130, 400604 Cluj-Napoca, Romania
Mariusz Adamski: Faculty of Civil and Environmental Engineering, Bialystok University of Technology, Wiejska 45E street, 15-351 Białystok, Poland
Sustainability, 2020, vol. 12, issue 14, 1-11
Abstract:
The presented research work is aimed at investigation of the influence of indoor environmental conditions on employees in office buildings. Monitoring of carbon dioxide, temperature, relative humidity and pulse, as well as subjective evaluation, was carried out in three office rooms where air conditioning systems ensured the required amount of fresh air. Investigation showed that in two offices (A and B), the amount of fresh air did not comply with EN 15251:2017. The concentration of CO 2 in office A was above 1000 ppm for 72% of the total length of stay. Respondents confirmed fatigue and headaches. In offices A and B, where CO 2 concentration was around 1000 ppm, people with a weight of up to 70 kg experienced a significant increase in air temperature as well as odor. Persons with weight higher than 75 kg experienced a slight decrease in air quality. In office C, where CO 2 concentration was around 800 ppm, respondents reported a slight decrease in air quality. According to pulse monitoring, it can be stated that in an office where there is an insufficient supply of fresh air, the pulse of a person falls or only slightly rises. A decrease in pulses may indicate the attenuation or stunning of people caused by poor air quality.
Keywords: office building; CO 2; temperature; relative humidity; pulse; questionnaire (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2020
References: View complete reference list from CitEc
Citations: View citations in EconPapers (4)
Downloads: (external link)
https://www.mdpi.com/2071-1050/12/14/5569/pdf (application/pdf)
https://www.mdpi.com/2071-1050/12/14/5569/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:12:y:2020:i:14:p:5569-:d:382842
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().