Study on Smoke Leakage Performance of Suspended Ceiling System

Tien-Lun Chou, Chieh-Hsin Tang, Ying-Ji Chuang and Ching-Yuan Lin
Additional contact information
Tien-Lun Chou: Department of Architecture, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
Chieh-Hsin Tang: Department of Architecture, China University of Technology, Taipei 11695, Taiwan
Ying-Ji Chuang: Department of Architecture, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
Ching-Yuan Lin: Department of Architecture, National Taiwan University of Science and Technology, Taipei 10607, Taiwan

Sustainability, 2020, vol. 12, issue 18, 1-13

Abstract: The key focus of the research is on the smoke leakage rate from suspended ceiling system, referencing CNS 15038 norm and its experimental principles to build a set of monitoring equipment for measuring air leakage rate and the provision of detailed assembly details for users’ reference. Through the real-size test chamber, the smoke insulation performance of the ceiling is studied. Targeting the different ceiling materials, ceiling panels dimensions, and construction methods, in keeping with the scientific principles of fluid mechanics, a total of 405 tests are carried out to come up with the means of appraising the leakage rate of ceiling panels of different sizes and materials. The study found that with the ceiling panel material quality being different, even if the ceiling size is the same, different leakage rates could occur. When the material quality of the ceiling panels is the same and the ceiling size is different, it is not that the larger the size of the panel, the greater the leakage rate, but the smallest leakage rate is caused by the largest panel and this is a very special phenomenon. This study also presents a leakage rate assessment table for entire ceiling panels, which will provide future calculations of the smoke leakage rate of the non-flame room, which can be extrapolated to assess the time of smoke decline and conducive for evacuation design. The apparatus has been proven to have proper leakage rate detection capability for the ceiling panels. In the future, the design principle of the extended system can be applied to the inspection and testing of smoke insulation capability of other fire prevention products. In turn, it can be estimated when the smoke has fallen to facilitate escape design.

Keywords: smoke leakage performance; suspended ceiling system; pressure difference (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2020
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/2071-1050/12/18/7244/pdf (application/pdf)
https://www.mdpi.com/2071-1050/12/18/7244/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:12:y:2020:i:18:p:7244-:d:408783

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:12:y:2020:i:18:p:7244-:d:408783