Experimental Study and Analysis of Thermal Comfort in a University Campus Building in Tropical Climate
Milen Balbis-Morejón,
Javier M. Rey-Hernández,
Carlos Amaris-Castilla,
Eloy Velasco-Gómez,
Julio F. San José-Alonso and
Francisco Javier Rey-Martínez
Additional contact information
Milen Balbis-Morejón: Department of Energy, Universidad de la Costa, Calle 58 No. 55-66, Barranquilla 080002, Colombia
Javier M. Rey-Hernández: Department of Energy and Fluid Mechanics, European University Miguel de Cervantes, Padre Julio Chevalier, 47012 Valladolid, Spain
Carlos Amaris-Castilla: Department of Energy, Universidad de la Costa, Calle 58 No. 55-66, Barranquilla 080002, Colombia
Eloy Velasco-Gómez: Department of Energy and Fluid Mechanics, Engineering School (EII), University of Valladolid, Paseo del Cauce 59, 47011 Valladolid, Spain
Julio F. San José-Alonso: Department of Energy and Fluid Mechanics, Engineering School (EII), University of Valladolid, Paseo del Cauce 59, 47011 Valladolid, Spain
Francisco Javier Rey-Martínez: Department of Energy and Fluid Mechanics, Engineering School (EII), University of Valladolid, Paseo del Cauce 59, 47011 Valladolid, Spain
Sustainability, 2020, vol. 12, issue 21, 1-18
Abstract:
This study presents the evaluation of the performance and acceptability of thermal comfort by students in the classrooms of a university building with minisplit-type air-conditioning systems, in a tropical climate. To carry out the study, temperature and humidity measurements were recorded, both outside and inside the selected classrooms, while the students were asked to complete thermal surveys on site. The survey model is based on the template proposed by Fanger and it was applied to a total number of 584 students. In each classroom, the Predicted Mean Vote (PMV) and the Predicted Percentage Dissatisfied (PPD) were estimated according to Fanger’s methodology, as well as the Thermal Sensation Vote (TSV) and the Actual Percentage Dissatisfied (APD), which were obtained from the measurements and the surveys. The results of this study showed that the PMV values, although they may vary with the insulation of the clothing, do not affect the TSV. Furthermore, comparing PMV vs. TSV scores, a 2 °C to 3 °C difference in operating temperature was found, whereby the thermal sensitivity for TSV was colder, so it could be assumed that the PMV model overestimates the thermal sensitivity of students in low-temperature conditions. In addition, an acceptability by 90% with thermal preferences between 23 °C and 24 °C were also found. These results indicate that it is possible to increase the temperature set point in minisplit-type air-conditioning system from 4 °C to 7 °C with respect to the currently set temperatures, without affecting the acceptability of the thermal environment to the students in the building.
Keywords: indoor environmental quality (IEQ); thermal comfort methods; thermal acceptability; tropical climate (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (4)
Downloads: (external link)
https://www.mdpi.com/2071-1050/12/21/8886/pdf (application/pdf)
https://www.mdpi.com/2071-1050/12/21/8886/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:12:y:2020:i:21:p:8886-:d:435040
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().