Analysis of the Calculation Method for the Thermal Transmittance of Double Windows Considering the Thermal Properties of the Air Cavity

Minjung Bae, Youngjun Lee, Gyeongseok Choi, Sunsook Kim and Jaesik Kang
Additional contact information
Minjung Bae: Department of Living and Built Environment Research, Korea Institute of Civil Engineering and Building Technology, Goyang 10223, Korea
Youngjun Lee: Institute of Environmental Building Facade Engineering, Bel Technology Co. Ltd., Seoul 05548, Korea
Gyeongseok Choi: Department of Living and Built Environment Research, Korea Institute of Civil Engineering and Building Technology, Goyang 10223, Korea
Sunsook Kim: Department of Architecture, College of Engineering, Ajou University, Suwon 16499, Korea
Jaesik Kang: Department of Living and Built Environment Research, Korea Institute of Civil Engineering and Building Technology, Goyang 10223, Korea

Sustainability, 2020, vol. 12, issue 24, 1-11

Abstract: The calculation method for the thermal transmittance (U-value) of double windows as specified by the Korean government (ISO 15099) is often inappropriate. To develop a more suitable calculation method, the thermal properties of the air cavity between the internal and external windows should be considered. Herein, seven cases of double windows were set up. The air cavities were designed in accordance with international standards and computational fluid dynamics (CFD) and used for the calculation of the U-values of the double windows according to ISO 15099 and 10077. All the calculated U-values were compared with experimentally obtained values. In accordance with the ISO 10077-1 method, the thermal resistance of the air cavity calculated using CFD could produce double window U-values that are similar to the experimentally obtained values. In most cases, the difference between the theoretical and experimental U-values was 5% and less than 0.14 W·m −2 ·K −1 , implying that the U-values calculated using CFD and the ISO 10077-1 method are approximately equal to the experimentally obtained U-values. Korean regulations do not include ISO 10077-1 for double-window assessment. However, these criteria can provide a solution in improving the accuracy of the calculation of the overall thermal transmittance of double windows.

Keywords: energy labeling program for windows; double windows; overall thermal transmittance of windows (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2020
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/2071-1050/12/24/10439/pdf (application/pdf)
https://www.mdpi.com/2071-1050/12/24/10439/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:12:y:2020:i:24:p:10439-:d:461655

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:12:y:2020:i:24:p:10439-:d:461655