A Fast Simulation Approach to the Thermal Recovery Characteristics of Deep Borehole Heat Exchanger after Heat Extraction
Yazhou Zhao,
Zhibo Ma and
Zhonghe Pang
Additional contact information
Yazhou Zhao: Key Laboratory of Shale Gas and Geoengineering, Institute of Geology and Geophysics, Chinese Academy of Sciences, Beijing 100029, China
Zhibo Ma: Institute of Applied Physics and Computational Mathematics, Beijing 100094, China
Zhonghe Pang: Key Laboratory of Shale Gas and Geoengineering, Institute of Geology and Geophysics, Chinese Academy of Sciences, Beijing 100029, China
Sustainability, 2020, vol. 12, issue 5, 1-27
Abstract:
Necessary intermittence after heat extraction for a deep borehole heat exchanger (DBHE) is beneficial for sustainable operation. This paper centers on the fast simulation for thermal recovery characteristics of DBHE under intermittent condition. First of all, in view of the existing temperature gradient and multi-layer heterogeneity of rock underground that could never be ignored for DBHE, we extend the classical finite line source model based on heat source theory and superposition principle to account for the vertical heat flux distribution varying along depth and heterogeneous thermal conductivities in the multi-layer rock zone. Moreover, a fast simulation approach for heat transfer analysis inside the borehole coupled with the extended finite line source model is put forward to depict the transient thermal response and dynamic thermal recovery of rock outside borehole. To the authors’ knowledge, no such algorithm for deep BHE has yet been suggested in the previous literature. This approach has proven to be reliable and efficient enough for DBHE simulation under the intermittent condition. Simulation results show that at least 65 days of intermittence for the model in study should be spared after the heating season to achieve sustainable heat extraction in the next cyclic operation. Compared to the detailed solution based on full discretization numerical schemes, the relative error for borehole bottom temperature was 0.79%. In addition, comparison of the simulation results for thermal performance during the heating season in a three-year cyclic operation with 205 days intermittence shows that both the outflow temperature and heat extraction rate in the subsequent cycle after intermittence are in good agreement with the full 3D numerical solution in the reference (with a relative error of 6.36% for the outflow temperature and 9.3% for the heat extraction rate). Regarding the calculation speed, around a 13 times acceleration can be achieved. Finally, it is also promising to be applicable for thermal recovery simulation after heat extraction of vertical closed loop borehole heat exchangers at arbitrary length from shallow to deep.
Keywords: deep borehole heat exchanger; thermal recovery; fast simulation; extended finite line source model; vertical heat flux distribution; heterogeneous thermal conductivities (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (6)
Downloads: (external link)
https://www.mdpi.com/2071-1050/12/5/2021/pdf (application/pdf)
https://www.mdpi.com/2071-1050/12/5/2021/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:12:y:2020:i:5:p:2021-:d:329202
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().