Analyzing the Effect of Parasitic Capacitance in a Full-Bridge Class-D Current Source Rectifier on a High Step-Up Push–Pull Multiresonant Converter
Anusak Bilsalam,
Chainarin Ekkaravarodome,
Viboon Chunkag and
Phatiphat Thounthong
Additional contact information
Anusak Bilsalam: Department of Electrical Engineering Technology, College of Industrial Technology (CIT), King Mongkut’s University of Technology North Bangkok (KMUTNB), 1518 Pracharat 1 Rd., Wongsawang, Bang Sue, Bangkok 10800, Thailand
Chainarin Ekkaravarodome: Advanced Power Electronics and Experiment Laboratory, Department of Instrumentation and Electronics Engineering, Faculty of Engineering, King Mongkut’s University of Technology North Bangkok (KMUTNB), 1518 Pracharat 1 Rd., Wongsawang, Bang Sue, Bangkok 10800, Thailand
Viboon Chunkag: Department Electrical and Computer Engineering, Faculty of Engineering, King Mongkut’s University of Technology North Bangkok (KMUTNB), 1518 Pracharat 1 Rd., Wongsawang, Bang Sue, Bangkok 10800, Thailand
Phatiphat Thounthong: Renewable Energy Research Centre, Department of Teacher Training in Electrical Engineering, Faculty of Technical Education, King Mongkut’s University of Technology North Bangkok (KMUTNB), 1518 Pracharat 1 Rd., Wongsawang, Bang Sue, Bangkok 10800, Thailand
Sustainability, 2021, vol. 13, issue 10, 1-19
Abstract:
This paper presents an analysis on the effect of a parasitic capacitance full-bridge class-D current source rectifier (FB-CDCSR) on a high step-up push–pull multiresonant converter (HSPPMRC). The proposed converter can provide high voltage for a 12 V DC battery using an isolated transformer and an FB-CDCSR. The main switches of the push–pull and diode full-bridge rectifier can be operated under a zero-current switching condition (ZCS). The advantages of this technique are that it uses a leakage inductance to achieve the ZCS for the power switch, and the leakage inductance and parasitic junction capacitance are used to design the secondary side of the resonant circuit. A prototype HSPPMRC was built and operated at 200 kHz fixed switching frequency, 340 V DC output voltage, and 250 W output power. In addition, the efficiency is equal to 96% at maximum load. Analysis of the effect of the parasitic junction capacitance on the full-bridge rectifier indicates that it has a significant impact on the operating point of the resonant tank and voltage. The proposed circuit design was verified via experimental results, which were found to be in agreement with the theoretical analysis.
Keywords: parasitic capacitance; high step-up; zero-current switching; multiresonant; converter; current source rectifier (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2021
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/2071-1050/13/10/5477/pdf (application/pdf)
https://www.mdpi.com/2071-1050/13/10/5477/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:13:y:2021:i:10:p:5477-:d:554204
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().