EconPapers    
Economics at your fingertips  
 

The Importance of In Situ Characterisation for the Mitigation of Poor Indoor Environmental Conditions in Social Housing

Rui Oliveira, Romeu Vicente, Ricardo M. S. F. Almeida and António Figueiredo
Additional contact information
Rui Oliveira: Research Center for Risks and Sustainability in Construction—RISCO, Department of Civil Engineering, Campus Universitário de Santiago, University of Aveiro, 3810-193 Aveiro, Portugal
Romeu Vicente: Research Center for Risks and Sustainability in Construction—RISCO, Department of Civil Engineering, Campus Universitário de Santiago, University of Aveiro, 3810-193 Aveiro, Portugal
Ricardo M. S. F. Almeida: Department of Civil Engineering, Campus Politécnico de Repeses, Polytechnic Institute of Viseu, 3504-510 Viseu, Portugal
António Figueiredo: Research Center for Risks and Sustainability in Construction—RISCO, Department of Civil Engineering, Campus Universitário de Santiago, University of Aveiro, 3810-193 Aveiro, Portugal

Sustainability, 2021, vol. 13, issue 17, 1-22

Abstract: The energy efficiency improvements in existing buildings have become priority concerns of the European Union to encourage energy efficiency amongst residents and buildings as well as facility managers. The characterisation of the building stock plays an important role in the definition of energy renovation strategies. In Portugal, there are over 120,000 social housing flats. This paper focused on the holistic characterisation of a social housing neighbourhood concerning the “in situ” assessment of the indoor environmental conditions and thermal comfort over one year as well as air permeability tests of the flats and evaluation of the energy consumption. The hygrothermal monitoring campaign was carried out using thermo-hygrometer sensors to record the indoor air temperature and relative humidity of a large number of flats over a 12-month period. The airtightness of these flats was determined resourcing fan pressurisation test (blower door test). A relationship between the users’ modifications in the flats and their consequence over the air permeability was pursued and the importance of balconies and exhaust fans for the flats’ air permeability was discussed. The hygrothermal monitoring campaign of the case study was carried out, in order to assess the indoor thermal comfort according the ASHRAE 55 standard. The results show a significant discomfort rate, suggesting that the users are living in unhealthy environmental conditions and the issues that most contribute to the poor indoor environmental conditions that characterise this building stock. In addition, the energy, gas, and water consumption of the flats were collected, and a statistical analysis was performed. Correlations between the variables were observed and two clusters were identified. Cluster 1 includes the lower energy consumption flats, but no real impact on the thermal comfort was found as the entire dataset presented low indoor air temperatures.

Keywords: air temperature monitoring; social housing; comfort assessment; building airtightness; energy and water consumption (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/2071-1050/13/17/9836/pdf (application/pdf)
https://www.mdpi.com/2071-1050/13/17/9836/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:13:y:2021:i:17:p:9836-:d:627330

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:13:y:2021:i:17:p:9836-:d:627330