EconPapers    
Economics at your fingertips  
 

Analysis of Harmonic Resonance Characteristics in Grid-Connected LCL Virtual Synchronous Generator

Jingya Jiang, Wei Wang, Xuezhi Wu, Fen Tang, Zhengwen Yang and Xiangjun Li
Additional contact information
Jingya Jiang: National Active Distribution Network Technology Research Center (NANTEC), Beijing Jiaotong University, Beijing 100044, China
Wei Wang: National Active Distribution Network Technology Research Center (NANTEC), Beijing Jiaotong University, Beijing 100044, China
Xuezhi Wu: National Active Distribution Network Technology Research Center (NANTEC), Beijing Jiaotong University, Beijing 100044, China
Fen Tang: National Active Distribution Network Technology Research Center (NANTEC), Beijing Jiaotong University, Beijing 100044, China
Zhengwen Yang: National Active Distribution Network Technology Research Center (NANTEC), Beijing Jiaotong University, Beijing 100044, China
Xiangjun Li: Key Laboratory of Control and Operation of Renewable Energy and Storage Systems, Energy Storage and Electrical Engineering Department, China Electric Power Research Institute, Beijing 100192, China

Sustainability, 2021, vol. 13, issue 8, 1-26

Abstract: The virtual synchronous generator (VSG), which emulates the essential behavior of the conventional synchronous generator, has attracted great attention. This paper proposes to analyze the harmonic resonance characteristics in VSG using the state-space model. The analysis is based on a full-order state-space small-signal model that fully considers the dynamic of the inner loops and the VSG-based outer power control loop. Participation analysis is used to point out the contributions of different states to the eigenvalues. Moreover, eigenvalue locus and singular value decomposition (SVD) are applied together to evaluate the impact of the inner loop parameters on the harmonic resonance characteristics around the LCL filter resonance frequency. The analysis indicates that the harmonic resonance instability is mainly caused by decreasing the proportional gains of the current loop and the voltage loop. Finally, extensive numerical simulation and experimental results are given to verify the validity of the theoretical analysis. Both the simulation and experimental results indicate that the voltage of the common coupling point is unstable after decreasing the proportional gains of the current and voltage controllers. As K pc decreases from 5 to 0.4 or K pv decreases from 0.6 to 0.2, the harmonic distortion factor (HDF) around the LCL filter resonance frequency increases. Furthermore, the consistency of simulation results, experimental results, and the theoretical analysis results is validated.

Keywords: virtual synchronous generator; harmonic resonance; state-space modeling; SVD; eigenvalue (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/2071-1050/13/8/4261/pdf (application/pdf)
https://www.mdpi.com/2071-1050/13/8/4261/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:13:y:2021:i:8:p:4261-:d:534448

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:13:y:2021:i:8:p:4261-:d:534448