EconPapers    
Economics at your fingertips  
 

Optimization of Corrugated Sheet Packing Structure Based on Analysis of Falling Film Flow Characteristics

Junhua Liao, Peng Xue, Ling Jin, Mengjing Zhao, Nan Zhang and Junjie Liu
Additional contact information
Junhua Liao: Beijing Key Laboratory of Green Building Environment and Energy Saving Technology, Beijing University of Technology, Beijing 100124, China
Peng Xue: Beijing Key Laboratory of Green Building Environment and Energy Saving Technology, Beijing University of Technology, Beijing 100124, China
Ling Jin: Beijing Key Laboratory of Green Building Environment and Energy Saving Technology, Beijing University of Technology, Beijing 100124, China
Mengjing Zhao: Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, China
Nan Zhang: Beijing Key Laboratory of Green Building Environment and Energy Saving Technology, Beijing University of Technology, Beijing 100124, China
Junjie Liu: Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China

Sustainability, 2022, vol. 14, issue 10, 1-19

Abstract: The falling film flow characteristics of a liquid on the surface of corrugated sheet packing are crucial for its mass transfer performance in various industrial applications. In this study, a falling film flow experiment with laser-induced fluorescence technology was conducted to validate the flow characteristics of a falling film simulated using computational fluid dynamics (CFD). The influences of Reynolds number (Re) and the packing structure on flow characteristics were analyzed with quantitative film thickness and wetted area obtained through three-dimensional simulation. The results show that the CFD model can accurately predict the liquid falling–film flow behavior and calculate the characteristic parameters. For sinusoidal corrugated sheets, when Re reaches 500, the groove flow changes into a rivulet flow along the adjacent ripples and the wetted area is at its largest, about 0.022 m 2 . However, relative to the geometric area of the corrugated sheet, the wetted area can only reach 20% of the surface area, and the overall wetting performance is still poor. Triangular and trapezoidal corrugated sheets were further proposed and proved to improve the wetting area compared with the sinusoidal sheet, with maximum increases of 23% and 9%, respectively. On this basis, extensive research was carried out on the corrugation angle. The results show that a triangular corrugated sheet with a 75° corrugated angle was more conducive to the flow of the liquid film, and the wetted area was 38.8% of the surface area.

Keywords: corrugated sheet packing; falling film flow; laser-induced fluorescence technology; computational fluid dynamics (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/2071-1050/14/10/5861/pdf (application/pdf)
https://www.mdpi.com/2071-1050/14/10/5861/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:14:y:2022:i:10:p:5861-:d:813925

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:14:y:2022:i:10:p:5861-:d:813925