EconPapers    
Economics at your fingertips  
 

Detection and Prevention of False Data Injection Attacks in the Measurement Infrastructure of Smart Grids

Muhammad Awais Shahid, Fiaz Ahmad, Fahad R. Albogamy, Ghulam Hafeez and Zahid Ullah
Additional contact information
Muhammad Awais Shahid: Department of Electrical & Computer Engineering, Air University, Islamabad 44230, Pakistan
Fiaz Ahmad: Department of Electrical & Computer Engineering, Air University, Islamabad 44230, Pakistan
Fahad R. Albogamy: Computer Sciences Program, Turabah University College, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia
Ghulam Hafeez: Department of Electrical Engineering, University of Engineering and Technology, Mardan 23200, Pakistan
Zahid Ullah: Department of Electrical Engineering, University of Management and Technology Lahore, Sialkot Campus, Sialkot 51310, Pakistan

Sustainability, 2022, vol. 14, issue 11, 1-25

Abstract: The smart grid has become a cyber-physical system and the more cyber it becomes, the more prone it is to cyber-attacks. One of the most important cyber-attacks in smart grids is false data injection (FDI) into its measurement infrastructure. This attack could manipulate the control center in a way to execute wrong control actions on various generating units, causing system instabilities that could ultimately lead to power system blackouts. In this study, a novel false data detection and prevention paradigm was proposed for the measurement infrastructure in smart grids. Two techniques were devised to manage cyber-attacks, namely, the fixed dummy value model and the variable dummy value model. Limitations of the fixed dummy value model were identified and addressed in the variable dummy value model. Both methods were tested on an IEEE 14 bus system and it was shown through the results that an FDI attack that easily bypassed the bad data filter of the state estimator was successfully identified by the fixed dummy model. Second, attacks that were overlooked by the fixed dummy model were identified by the variable dummy method. In this way, the power system was protected from FDI attacks.

Keywords: smart grid; cyber-physical system; false data injection attacks; false data detection; cyber security (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/2071-1050/14/11/6407/pdf (application/pdf)
https://www.mdpi.com/2071-1050/14/11/6407/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:14:y:2022:i:11:p:6407-:d:822760

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:14:y:2022:i:11:p:6407-:d:822760