The Possibility of Providing Acoustic Comfort in Hotel Rooms as an Element of Sustainable Development
Krzysztof Nering (),
Alicja Kowalska-Koczwara,
Anna Shymanska and
Michał Pawluś
Additional contact information
Krzysztof Nering: Faculty of Civil Engineering, Cracow University of Technology, 31-155 Krakow, Poland
Alicja Kowalska-Koczwara: Faculty of Civil Engineering, Cracow University of Technology, 31-155 Krakow, Poland
Anna Shymanska: Electromechanics Department, Electrical Power Engineering and Automation Faculty, Igor Sikorsky Kyiv Polytechnic Institute, 03056 Kyiv, Ukraine
Michał Pawluś: Faculty of Civil Engineering, Cracow University of Technology, 31-155 Krakow, Poland
Sustainability, 2022, vol. 14, issue 20, 1-21
Abstract:
The noise problem in hotel rooms is strictly connected to noise generated by heating, ventilating, and air conditioning (HVAC) devices. Hospitality industry companies in many countries have specific requirements and monitor the noise level with technical equipment inside the hotel room. To ensure an adequately low level of noise from the HVAC system, proper calculations and tests are performed before the final application of the system in the hotel room. One of the best methods for assessing the noise level from HVAC devices in hotel rooms is to create a testing room (mock-up) in a certain available space, e.g., in a warehouse, and to perform appropriate standard measurements for the noise level. This method is a popular choice in the hotel industry because the noise level can not only be verified, but also, the installation and operation of the HVAC system inside the room can be checked. The main factors in choosing the space in which the mock-up will be made are availability and appropriate volume. It is not always possible to provide a hall space with a very low background level of noise. This article shows that the selection of a mock-up space is also determined by the noise level in the selected space. The background noise level—thus, the noise level in the mock-up room—must be low enough to be able to reliably measure the noise level from the HVAC equipment to avoid the phenomenon of acoustic masking by other noise sources (background noise) not related to the measurement. Background noise at too high a level will lead to invalidation of the measurement results or overestimation of the actual noise level in the room from the tested HVAC devices. In this study, background noise level measurements made in the testing rooms are described. The results are discussed, and a conclusion is drawn.
Keywords: sustainable comfort; acoustic comfort; noise; HVAC devices (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/2071-1050/14/20/13692/pdf (application/pdf)
https://www.mdpi.com/2071-1050/14/20/13692/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:14:y:2022:i:20:p:13692-:d:950128
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().