Dynamic Stability Evaluation of an Integrated Biodiesel-Geothermal Power Plant-Based Power System with Spotted Hyena Optimized Cascade Controller
Arindita Saha,
Puja Dash,
Naladi Ram Babu,
Tirumalasetty Chiranjeevi,
Mudadla Dhananjaya and
Łukasz Knypiński ()
Additional contact information
Arindita Saha: Department of Electrical Engineering, Regent Education & Research Foundation Group of Institutions, Kolkata 700121, West Bengal, India
Puja Dash: Department of Electrical and Electronics Engineering, Gayatri Vidya Parishad College of Engineering (Autonomous), Visakhapatnam 530048, Andhra Pradesh, India
Naladi Ram Babu: Department of Electrical & Electronics Engineering, Aditya Engineering College, Surampalem 533437, Andhra Pradesh, India
Tirumalasetty Chiranjeevi: Department of Electrical Engineering, Rajkiya Engineering College Sonbhadra, Churk 231206, Uttar Pradesh, India
Mudadla Dhananjaya: Department of EEE, Anil Neerukonda Institute of Technology and Science (A), Visakhapatnam 531162, Andhra Pradesh, India
Łukasz Knypiński: Faculty of Automatic Control, Robotic and Electrical Engineering, Poznan University of Technology, 60-965 Poznan, Poland
Sustainability, 2022, vol. 14, issue 22, 1-26
Abstract:
The perception of automatic generation control (AGC) has a massive part in delivering eminence power in an interrelated structure. To acquire eminence power by monitoring the fluctuations of frequency and tie-link power, an appropriate controller strategy is essential. This work explores AGC learning under the traditional situation. In this study, we employ a cascade controller with proportional amalgamation with a tilt-integral-derivative with a filter (TIDN) and fractional order integral-derivative (FOID), named TIDN-FOID. In order to acquire the controller’s attributes, a meta-heuristic optimization algorithm spotted hyena optimizer (SHO) is employed. Several investigations express the excellency of the TIDN-FOID controller over other controllers from outlook regarding the lessened level of peak_overshoot, peak_undershoot, and settling_time for the considered structure. The structure comprises thermal, biodiesel units in area 1, thermal, and geothermal units in area-2, and hydrothermal units in area-3. Both biodiesel and GPP have a better effect on system dynamics even in the presence of time delay. Action in the redox flow battery is also examined, providing a noteworthy outcome. Eigenvalue assessment is carried out to comment on the stability of the system. TIDN-FOID parameter values at nominal conditions are appropriate for a higher disturbance value without the need for optimization.
Keywords: automatic generation control; geothermal power plant; redox flow battery; biodiesel plant; spotted hyena optimizer; particle swarm optimization; controller; time delay (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/2071-1050/14/22/14842/pdf (application/pdf)
https://www.mdpi.com/2071-1050/14/22/14842/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:14:y:2022:i:22:p:14842-:d:968772
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().