Dynamic Stability Evaluation of an Integrated Biodiesel-Geothermal Power Plant-Based Power System with Spotted Hyena Optimized Cascade Controller

Arindita Saha, Puja Dash, Naladi Ram Babu, Tirumalasetty Chiranjeevi, Mudadla Dhananjaya and Łukasz Knypiński ()
Additional contact information
Arindita Saha: Department of Electrical Engineering, Regent Education & Research Foundation Group of Institutions, Kolkata 700121, West Bengal, India
Puja Dash: Department of Electrical and Electronics Engineering, Gayatri Vidya Parishad College of Engineering (Autonomous), Visakhapatnam 530048, Andhra Pradesh, India
Naladi Ram Babu: Department of Electrical & Electronics Engineering, Aditya Engineering College, Surampalem 533437, Andhra Pradesh, India
Tirumalasetty Chiranjeevi: Department of Electrical Engineering, Rajkiya Engineering College Sonbhadra, Churk 231206, Uttar Pradesh, India
Mudadla Dhananjaya: Department of EEE, Anil Neerukonda Institute of Technology and Science (A), Visakhapatnam 531162, Andhra Pradesh, India
Łukasz Knypiński: Faculty of Automatic Control, Robotic and Electrical Engineering, Poznan University of Technology, 60-965 Poznan, Poland

Sustainability, 2022, vol. 14, issue 22, 1-26

Abstract: The perception of automatic generation control (AGC) has a massive part in delivering eminence power in an interrelated structure. To acquire eminence power by monitoring the fluctuations of frequency and tie-link power, an appropriate controller strategy is essential. This work explores AGC learning under the traditional situation. In this study, we employ a cascade controller with proportional amalgamation with a tilt-integral-derivative with a filter (TIDN) and fractional order integral-derivative (FOID), named TIDN-FOID. In order to acquire the controller’s attributes, a meta-heuristic optimization algorithm spotted hyena optimizer (SHO) is employed. Several investigations express the excellency of the TIDN-FOID controller over other controllers from outlook regarding the lessened level of peak_overshoot, peak_undershoot, and settling_time for the considered structure. The structure comprises thermal, biodiesel units in area 1, thermal, and geothermal units in area-2, and hydrothermal units in area-3. Both biodiesel and GPP have a better effect on system dynamics even in the presence of time delay. Action in the redox flow battery is also examined, providing a noteworthy outcome. Eigenvalue assessment is carried out to comment on the stability of the system. TIDN-FOID parameter values at nominal conditions are appropriate for a higher disturbance value without the need for optimization.

Keywords: automatic generation control; geothermal power plant; redox flow battery; biodiesel plant; spotted hyena optimizer; particle swarm optimization; controller; time delay (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/2071-1050/14/22/14842/pdf (application/pdf)
https://www.mdpi.com/2071-1050/14/22/14842/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:14:y:2022:i:22:p:14842-:d:968772

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:14:y:2022:i:22:p:14842-:d:968772