EconPapers    
Economics at your fingertips  
 

Aquila Optimization Based Harmonic Elimination in a Modified H-Bridge Inverter

Md Reyaz Hussan, Mohammad Irfan Sarwar, Adil Sarwar, Mohd Tariq, Shafiq Ahmad, Adamali Shah Noor Mohamed, Irfan A. Khan and Mohammad Muktafi Ali Khan
Additional contact information
Md Reyaz Hussan: Department of Electrical Engineering, Zakir Husain College of Engineering and Technology (ZHCET), Aligarh Muslim University, Aligarh 202002, India
Mohammad Irfan Sarwar: Grenoble Institute of Technology—Ense3, Université Grenoble Alpes, 38400 Grenoble, France
Adil Sarwar: Department of Electrical Engineering, Zakir Husain College of Engineering and Technology (ZHCET), Aligarh Muslim University, Aligarh 202002, India
Mohd Tariq: Department of Electrical Engineering, Zakir Husain College of Engineering and Technology (ZHCET), Aligarh Muslim University, Aligarh 202002, India
Shafiq Ahmad: Industrial Engineering Department, College of Engineering, King Saud University, P.O. Box 800, Riyadh 11421, Saudi Arabia
Adamali Shah Noor Mohamed: Electrical Engineering Department, College of Engineering, King Saud University, P.O. Box 800, Riyadh 11421, Saudi Arabia
Irfan A. Khan: Department of Marine Engineering Technology in a Joint Appointment with the Department of Electrical and Computer Engineering, Texas A & M University, Galveston, TX 77553, USA
Mohammad Muktafi Ali Khan: Department of Electrical Engineering, Zakir Husain College of Engineering and Technology (ZHCET), Aligarh Muslim University, Aligarh 202002, India

Sustainability, 2022, vol. 14, issue 2, 1-16

Abstract: Multilevel inverters (MLIs) are capable of producing high-quality output voltage and handling large amounts of power. This reduces the size of the filter while also simplifying the circuitry. As a result, they have a wide range of applications in industries, particularly in smart grids. The input voltage boosting feature is required to use the MLI with renewable energy. Moreover, many components are required to get higher output voltage levels that add weight and cost to the circuit. Numerous MLI topologies have been identified to minimize the losses, device count, and device ratings. A seven-level modified H-bridge inverter with a reduced component count, and reduced THD is presented in this paper. Two DC sources with six IGBTs have been used to generate a seven-level output voltage, and the Aquila Optimizer (AO) has been implemented to get the regulated output. MATLAB/Simulink environment has been used for designing the simulation model. Furthermore, the simulation result has been validated in the laboratory on a hardware setup using the DSP-TMS320F28335 Launchpad. With the reduced number of switching devices as well as the dc supply, the size of the inverter is compacted and becomes more economical.

Keywords: cascaded H-bridge (CHB); multilevel inverter (MLI); aquila optimizer (AO); total harmonic distortion (THD) (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations: View citations in EconPapers (5)

Downloads: (external link)
https://www.mdpi.com/2071-1050/14/2/929/pdf (application/pdf)
https://www.mdpi.com/2071-1050/14/2/929/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:14:y:2022:i:2:p:929-:d:724846

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:14:y:2022:i:2:p:929-:d:724846