EconPapers    
Economics at your fingertips  
 

Experimental and Numerical Mechanical Characterization of Unreinforced and Reinforced Masonry Elements with Weak Air Lime Mortar Joints

Giuseppe Brando, Gianluca Vacca, Francesco Di Michele, Ilaria Capasso and Enrico Spacone
Additional contact information
Giuseppe Brando: Department of Engineering and Geology, University “G. d’Annunzio” of Chieti-Pescara, 65127 Pescara, Italy
Gianluca Vacca: Department of Engineering and Geology, University “G. d’Annunzio” of Chieti-Pescara, 65127 Pescara, Italy
Francesco Di Michele: Department of Engineering and Geology, University “G. d’Annunzio” of Chieti-Pescara, 65127 Pescara, Italy
Ilaria Capasso: Department of Engineering and Geology, University “G. d’Annunzio” of Chieti-Pescara, 65127 Pescara, Italy
Enrico Spacone: Department of Engineering and Geology, University “G. d’Annunzio” of Chieti-Pescara, 65127 Pescara, Italy

Sustainability, 2022, vol. 14, issue 7, 1-18

Abstract: This paper deals with the results of an experimental and numerical campaign aimed at characterizing the mechanical response of masonry components and panels made of limestone units kept together by weak air lime mortar joints. The selected air lime mortar, typical of ancient masonry buildings but difficult to be built-up artificially, was specifically prepared for the experimental analyses, with the aim of obtaining a laboratory compression strength of 0.25–0.50 MPa. In the first part of the paper, the performed tests concerning the strength of the units (mean compression strength of 80 MPa) and of the mortar (mean compression strength after 28 days of 0.30 MPa), are described for different curing periods. Moreover, tests of masonry triplets in shear (shear strength of 0.11 MPa for null axial forces) are shown and used in order to establish the main parameters of the Mohr–Coulomb failure criterium. Then, the calibration of a continuous numerical micro-model implemented in Kratos Multiphysics is presented. The model is used for reproducing the behavior of an unreinforced panel in shear made of the studied masonry and to appraise the effectiveness of a FRCM- (Fiber Reinforced Cementitious Matrix) based reinforcement intervention applied. The obtained results proved that FRCM allows to increase the strength of the considered masonry type by about eight times and the ductility by about thirteen times.

Keywords: air lime mortar; masonry; micro-models; FRCM; masonry retrofitting; sustainable retrofitting (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/2071-1050/14/7/3990/pdf (application/pdf)
https://www.mdpi.com/2071-1050/14/7/3990/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:14:y:2022:i:7:p:3990-:d:781425

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:14:y:2022:i:7:p:3990-:d:781425