EconPapers    
Economics at your fingertips  
 

Precision Ventilation in an Open-Plan Office: A New Application of Active Chilled Beam (ACB) with a JetCone Feature

Haider Latif, Samira Rahnama, Alessandro Maccarini, Goran Hultmark, Peter V. Nielsen and Alireza Afshari
Additional contact information
Haider Latif: The Department of the Built Environment, Aalborg University, 2450 Copenhagen, Denmark
Samira Rahnama: The Department of the Built Environment, Aalborg University, 2450 Copenhagen, Denmark
Alessandro Maccarini: The Department of the Built Environment, Aalborg University, 2450 Copenhagen, Denmark
Goran Hultmark: Indoor Climate Solutions, Lindab A/S, 3520 Haderslev, Denmark
Peter V. Nielsen: The Department of the Built Environment, Aalborg University, 2450 Copenhagen, Denmark
Alireza Afshari: The Department of the Built Environment, Aalborg University, 2450 Copenhagen, Denmark

Sustainability, 2022, vol. 14, issue 7, 1-17

Abstract: Mixing ventilation systems effectively improves thermal comfort in open-spaces due to adequate turbulent mixing of the cold stream with ambient air. This study introduces the concept of precision ventilation for achieving local thermal comfort in a mixing ventilation system. This precision ventilation system provides asymmetrical airflows from an active chilled beam (ACB) to each of the office occupants. These ACBs provide air velocities with different magnitudes and directions. To achieve different magnitudes and directions, JetCones are used to vary the airflow in different parts of the ACB. The performance of the precision ventilation system was analyzed using full-scale laboratory experiments and computational fluid dynamic (CFD) simulations. The full-scale laboratory experiments were conducted in a 4.2 m × 3 m × 2.8 m (L × W × H) thermal isolated room with an open-plan dual desk-chair setup. The jet-cones in the ACB unit were adjusted to throw the required amount of flow to the occupants. The occupants had different metabolic rates of 1.2, 1.4, and 1.6 in a warm office space. The room set point temperatures varied between 23 and 26 °C. The experimental and CFD results show that occupants facing symmetrical airflow distribution and with a constant 1.2 metabolic rate had a similar PMV index. The occupants with 1.2, 1.4, and 1.6 metabolic rate were exposed to asymmetrical airflows, i.e., 30%, 58%, and 70% of the total airflow. Occupants with higher metabolic rates were kept thermally neutral, in the −0.5 to +0.5 PMV range, by increasing the air velocity and room temperature to 0.4 m/s and 25 °C, respectively.

Keywords: active chilled beams; asymmetrical airflows; JetCones; metabolic rates; precision ventilation (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/2071-1050/14/7/4242/pdf (application/pdf)
https://www.mdpi.com/2071-1050/14/7/4242/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:14:y:2022:i:7:p:4242-:d:786141

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:14:y:2022:i:7:p:4242-:d:786141