EconPapers    
Economics at your fingertips  
 

Investigation on Subjects’ Seasonal Perception and Adaptive Actions in Naturally Ventilated Hostel Dormitories in the Composite Climate Zone of India

Sanjay Kumar, Manoj Kumar Singh, Nedhal Al-Tamimi, Badr S. Alotaibi and Mohammed Awad Abuhussain
Additional contact information
Sanjay Kumar: Mechanical Engineering Department, Dr. B R Ambedkar National Institute of Technology, Jalandhar 144011, Punjab, India
Manoj Kumar Singh: National Institute of Technology Arunachal Pradesh, Jote, Papum Pare 791123, Arunachal Pradesh, India
Nedhal Al-Tamimi: Architectural Engineering Department, College of Engineering, Najran University, Najran 66462, Saudi Arabia
Badr S. Alotaibi: Architectural Engineering Department, College of Engineering, Najran University, Najran 66462, Saudi Arabia
Mohammed Awad Abuhussain: Architectural Engineering Department, College of Engineering, Najran University, Najran 66462, Saudi Arabia

Sustainability, 2022, vol. 14, issue 9, 1-18

Abstract: A seasonal adaptive thermal comfort study was done on university students in naturally ventilated dormitories in the composite climate zone of India. A total of 1462 responses were collected from the students during the field study spread over the autumn, winter, spring, and summer seasons of the academic year for 2018 and 2019. A “Right Here Right Now” type of surveying method was adopted, and the indoor thermal parameters were recorded simultaneously using high-grade instruments. The subjects’ mean thermal sensation (TS) was skewed towards a slightly cool feeling for the combined data. Most occupants preferred a cooler thermal environment during the summer season, while hostel residents desired a warmer temperature during autumn, winter, and spring seasons. During the summer season, the PMV−PPD model overestimated the subjects’ actual thermal sensation, while it underestimated the their thermal sensation in the winter season. The mean comfort temperature T comf was observed to be close to 27.1 (±4.65 °C) for the pooled data. Mean clo values of about 0.57 (±0.25), 0.98 (±0.12), 0.45 (±0.27), and 0.36 (±0.11) were recorded during the autumn, winter, spring, and summer seasons, respectively. Furthermore, switching on ceiling fans and opening doors and windows improved occupants’ thermal satisfaction during different seasons. The study results show the effective use of environmental controls and the role of thermal adaptation in enhancing the subjects/overall thermal satisfaction in the composite climate of India.

Keywords: field surveys; thermal perceptions; adaptive actions; hostel dormitories; composite climate of India (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)

Downloads: (external link)
https://www.mdpi.com/2071-1050/14/9/4997/pdf (application/pdf)
https://www.mdpi.com/2071-1050/14/9/4997/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:14:y:2022:i:9:p:4997-:d:798965

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:14:y:2022:i:9:p:4997-:d:798965