Integrated Thermodynamic and Control Modeling of an Air-to-Water Heat Pump for Estimating Energy-Saving Potential and Flexibility in the Building Sector
Dhirendran Munith Kumar,
Pietro Catrini,
Antonio Piacentino () and
Maurizio Cirrincione
Additional contact information
Dhirendran Munith Kumar: Department of Engineering, University of Palermo, Viale Delle Scienze, 90128 Palermo, Italy
Pietro Catrini: Department of Engineering, University of Palermo, Viale Delle Scienze, 90128 Palermo, Italy
Antonio Piacentino: Department of Engineering, University of Palermo, Viale Delle Scienze, 90128 Palermo, Italy
Maurizio Cirrincione: School of Information Technology, Engineering, Mathematics and Physics, The University of the South Pacific (USP), Laucala Campus, Private Mail Bag, Suva P.O. Box 1168, Fiji Islands
Sustainability, 2023, vol. 15, issue 11, 1-23
Abstract:
Reversible heat pumps are increasingly adopted for meeting the demand for space heating and cooling in buildings. These technologies will play a key role not only in the decarbonization of space air conditioning but also in the development of 100% renewable energy systems. However, to assess the achievable benefits through the adoption of these technologies in novel applications, reliable models are needed, capable of simulating both their steady-state operation and dynamic response at different conditions in terms of heating loads, outdoor temperatures, and so on. The operation of heat pumps is often investigated by highly simplified models, using performance data drawn from catalogs and paying scarce attention to the critical influence of controllers. In this respect, this paper proposed an integrated thermodynamic and control modeling for a reversible air-to-water heat pump. The study considered a heat pump alternatively equipped with variable-speed compressors and constant-speed compressors with sequential control. The developed modeling was then used to investigate the operation of an air-to-water heat pump serving an office building in Italy. Results show that the model provided insights into the transient operation of variable-speed heat pumps (e.g., the settling time). Regarding constant-speed heat pumps, the model provided hints of interest to the control engineer to prevent, in the examined case study, the risk of quick compressors cycling on low-load heating days or when low-temperature heating devices are supplied. Finally, using a control strategy based on a heating curve for the variable-speed heat pump, results show the potential for a sensible increase in the average coefficient of performance, from 17% up to 50%.
Keywords: energy saving; space heating; heat pumps; controllers; thermodynamic modeling; dynamic response; variable speed drive; sequential control (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/2071-1050/15/11/8664/pdf (application/pdf)
https://www.mdpi.com/2071-1050/15/11/8664/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:15:y:2023:i:11:p:8664-:d:1156852
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().