Indoor Air Quality Improvement in Public Toilets at Railway Stations in China: A Field and Numerical Study
Jinghua Yu (),
Congcong Qian,
Jingang Zhao,
Junwei Tao,
Kangxin Leng and
Xinhua Xu
Additional contact information
Jinghua Yu: School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
Congcong Qian: School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
Jingang Zhao: School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
Junwei Tao: School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
Kangxin Leng: School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
Xinhua Xu: School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
Sustainability, 2023, vol. 15, issue 11, 1-26
Abstract:
This study investigated the air quality and ventilation systems of 22 public toilets in 10 railway stations in China. Approximately 80% of public toilets meet the standard for ammonia concentration in Class I toilets, while 20% exceed the standard. It was found that the concentration of pollutants is mainly related to the number of toilet users and the ventilation system. In 20% of public toilets, the change in ammonia concentration was delayed by about 1 to 2 h with the change in hourly service number. In order to improve the air quality, a design method for calculating the number of toilet cubicles was proposed. Results show that the service capacity of the cubicle per hour (SCCH) of a female toilet is 12, the SCCH of male toilets is related to the ratio of squatting pans to urinals (RSU), which is suggested to be 1:1~1:0.8, and the corresponding SCCH is 16~20. Then, the effect of different ventilation forms was simulated by computational fluid dynamics (CFD) 2019 software. The results show that the bottom exhaust was better than the top exhaust and that the fresh air supply system is unnecessary. The recommended ventilation rate for toilets is 20 air changes per hour (ACH). The scale design method of toilets proposed in this paper was meant to address the gender imbalance and avoid queuing and provides a reference for the renovation and design of public toilets.
Keywords: air quality; ammonia concentration; ventilation system; public toilet; railway station (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/2071-1050/15/11/8720/pdf (application/pdf)
https://www.mdpi.com/2071-1050/15/11/8720/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:15:y:2023:i:11:p:8720-:d:1158183
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().