Structural Grading and Characteristic Value of the Moso Bamboo Culm Based on Its Minimum External Diameter
Rui Ma,
Zhihua Chen,
Yansheng Du () and
Lingao Jiao
Additional contact information
Rui Ma: School of Civil Engineering, Tianjin University, Tianjin 300072, China
Zhihua Chen: School of Civil Engineering, Tianjin University, Tianjin 300072, China
Yansheng Du: School of Civil Engineering, Tianjin University, Tianjin 300072, China
Lingao Jiao: School of Civil Engineering, Tianjin University, Tianjin 300072, China
Sustainability, 2023, vol. 15, issue 15, 1-22
Abstract:
Bamboo culm has been regarded as a traditional element in construction; meanwhile, it has great potential for the construction of rural houses to achieve green and low-carbon development. However, traditional bamboo houses are usually constructed according to previous experience, and it is hard to design bamboo houses in a standard way. Structural grading of the bamboo culm is an essential work to achieve standardization design. Grading the Moso bamboo culm ( P. edulis ) based on its minimum external diameter is proposed in this paper. The geometric, physical and mechanical properties of 883 Moso bamboo culms with three different treatment processes were measured and analyzed, namely untreated, with chemical preservatives and heat treatment. It was found that the external diameter of the Moso bamboo culm could be determined by the perimeter in practice. The treatment process has a great influence on the geometric, physical and mechanical properties. Bamboo culms with three different treatment processes could be divided into five, five and four grades, respectively. Meanwhile, based on measurement data, the characteristic values of each grade are presented, including the wall thickness, external and internal taper, linear mass, nominal density and compressive strength. The minimum chemical treatment factor is 0.785, 0.662 and 0.649, while the minimum heat treatment factor is 0.722, 0.644 and 0.877 for wall thickness, linear mass and nominal density, respectively. The treatment factor for compressive strength is 1.12 and 1.52 of chemical treatment and heat treatment, respectively. This study may aid establishing technical specifications and a standard design method for Moso bamboo structural building.
Keywords: Moso bamboo culm; structural grading; characteristic value (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/2071-1050/15/15/11647/pdf (application/pdf)
https://www.mdpi.com/2071-1050/15/15/11647/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:15:y:2023:i:15:p:11647-:d:1204607
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().