Error Influence Simulation of the 500 m Aperture Spherical Radio Telescope Cable-Net Structure Based on Random Combinations
Lulu Wang,
Mingmin Ding (),
Yangjie Ruan,
Bin Luo and
Jianchen Guo
Additional contact information
Lulu Wang: College of Civil Engineering, Nanjing Forestry University, Nanjing 210037, China
Mingmin Ding: College of Civil Engineering, Nanjing Forestry University, Nanjing 210037, China
Yangjie Ruan: National Prestress Engineering Research Center, Key Laboratory of C & PC Structures of Ministry of Education Southeast University, Nanjing 210096, China
Bin Luo: National Prestress Engineering Research Center, Key Laboratory of C & PC Structures of Ministry of Education Southeast University, Nanjing 210096, China
Jianchen Guo: College of Civil Engineering, Nanjing Forestry University, Nanjing 210037, China
Sustainability, 2023, vol. 15, issue 20, 1-17
Abstract:
The reflector of a Chinese 500 m aperture spherical radio telescope is supported by a giant cable-net structure. In the actual operation process, active displacement observation is realized by connecting the actuators with the control cables to adjust the cable net, which requires high manufacturing and installation accuracy. In this study, an error sensitivity computing method based on a normal distribution is adopted to perform single-error computing and multi-error coupling computing and to investigate the effect of the length error of all the cables, tensioning force error of active surface cables, and installation error of external nodes on the cable force. The results show that the length error of the surface cables and the installation error of the external nodes are the main factors affecting the cable force, while the length error of the control cables is a secondary factor. The coupling effect of multiple errors is not the linear superposition of each error’s influence; therefore, all the error factors should be comprehensively considered for coupling computing to determine the control index. Through multi-error coupling computing, it is determined that the length error limits of the surface cables and control cables are ±1.5 mm and ±20 mm, respectively, the tensioning force error limit of the active surface cables is ±10%, and the installation error limit of the external nodes is ±50 mm.
Keywords: giant cable-net structure; error influence computing; single-error computing; multi-error coupling computing (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/2071-1050/15/20/15061/pdf (application/pdf)
https://www.mdpi.com/2071-1050/15/20/15061/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:15:y:2023:i:20:p:15061-:d:1263219
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().