Architectural Design Strategies for Enhancement of Thermal and Energy Performance of PCMs-Embedded Envelope System for an Office Building in a Typical Arid Saharan Climate
Abdelkader Sarri,
Saleh Nasser Al-Saadi (),
Müslüm Arıcı,
Djamel Bechki and
Hamza Bouguettaia
Additional contact information
Abdelkader Sarri: Laboratory of New and Renewable Energies in Arid Zones (LENREZA), Kasdi Merbah University, Ouargla 30000, Algeria
Saleh Nasser Al-Saadi: Department of Civil and Architectural Engineering, College of Engineering, Sultan Qaboos University, P.O. Box 33, Al-Khoudh 123, Oman
Müslüm Arıcı: Engineering Faculty, Mechanical Engineering Department, Kocaeli University, Umuttepe Campus, Kocaeli 41001, Turkey
Djamel Bechki: Laboratory of New and Renewable Energies in Arid Zones (LENREZA), Kasdi Merbah University, Ouargla 30000, Algeria
Hamza Bouguettaia: Laboratory of New and Renewable Energies in Arid Zones (LENREZA), Kasdi Merbah University, Ouargla 30000, Algeria
Sustainability, 2023, vol. 15, issue 2, 1-29
Abstract:
The literature showed many studies that evaluated single or multiple Phase change materials (PCMs) layers in passive, active, or in hybrid configurations for building applications. However, little attention has been given to evaluating the energy performance of buildings when PCMs are used together with other passive design strategies. In this work, the energy performance of an office building in a typical arid Saharan climate is simulated using EnergyPlus when a PCMs-embedded envelope is implemented. The office building was analyzed without/with PCMs using various thicknesses. Results indicated that the annual electrical energy for heating, ventilation and air conditioning (HVAC) could be reduced between 3.54% and 6.18%, depending on the PCM thickness. The performance of the office building, including PCMs, was then simulated using two practical architectural design strategies, namely windows-to-wall ratio (WWR) and rezoning of the interior spaces. Outcomes revealed that the annual energy consumption for HVAC can be reduced from 10% to 15.5% and from 6.1% and 8.54% when WWR is reduced by half to three-quarters, and the perimeter zones are enlarged by one-third to two-thirds of the original space area, respectively. By combining both architectural design strategies and PCM, the annual electrical HVAC energy can be reduced between 12.08% and 15.69%, depending on the design configuration and PCM thickness. This design option provides additional benefits also since it reduces the vulnerability of increasing the lighting and fuel gas heating energy because more perimeter zones are exposed to daylighting and solar radiation, respectively.
Keywords: architectural design; building energy simulation; energy efficiency; PCMs; thermal insulation (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/2071-1050/15/2/1196/pdf (application/pdf)
https://www.mdpi.com/2071-1050/15/2/1196/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:15:y:2023:i:2:p:1196-:d:1029532
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().