A Critical Analysis of the Energy Requirements of a Commercial Building Based on Various Types of Glass Insulations
Israr Ahmed,
Jamal Umer,
Abdullah Altamimi (),
Ahmad Raza Khan Rana,
Zafar A. Khan,
Muhammad Imran,
Muhammad Awais and
Saeed Alyami ()
Additional contact information
Israr Ahmed: Department of Mechanical Engineering, University of Engineering and Technology Lahore, Lahore 54890, Pakistan
Jamal Umer: Department of Mechanical Engineering, University of Engineering and Technology Lahore, Lahore 54890, Pakistan
Abdullah Altamimi: Department of Electrical Engineering, College of Engineering, Majmaah University, Al-Majmaah 11952, Saudi Arabia
Ahmad Raza Khan Rana: Integrity Products & Supplies Inc., Sherwood Park, AB T8H 0B8, Canada
Zafar A. Khan: Electrical Engineering Department, Mirpur University of Science and Technology, Mirpur (A.K.) 10250, Pakistan
Muhammad Imran: Mechanical, Biomedical, and Design Engineering, College of Engineering and Physical Sciences, Aston University, Birmingham B4 7ET, UK
Muhammad Awais: College of Engineering and Physical Sciences, University of Birmingham, Birmingham B15 2TT, UK
Saeed Alyami: Department of Electrical Engineering, College of Engineering, Majmaah University, Al-Majmaah 11952, Saudi Arabia
Sustainability, 2023, vol. 15, issue 4, 1-21
Abstract:
Heat loss through the building envelope comprises air leaks through the cracks and largely through the windows, which is the weakest link of the thermal envelope. Therefore, it is necessary to devise a systematic approach to analyze the rightful selection of glass for buildings. The investigation is to analyze the energy-saving potential of different glasses and their comparisons to the initial capital cost to find the payback time in terms of energy saving by using two different types of equipment. The quantitative simulation study was completed on the Hourly Analysis Program (HAP) to analyze the annual energy consumption of the HVAC system for seven glasses and two types of chilled water equipment. The results show that the performance glasses with a tint had better efficiency in terms of energy saving, with a payback time of 3–7 months. A comparison of all glasses illustrated that float glass contributes the most to the total cooling load among all glasses, which were 5.04%, 5.7%, 7.6%, and 8.9% for the N, S, E, and W orientations, respectively. Moreover, the lowest contribution of glass to the total cooling load was given by tinted double-glazed glass, which was 2%, 2.3%, 3.0%, and 3.01% for N, S, E, and W orientations, respectively.
Keywords: building energy; energy efficiency; HVAC; glass insulation (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/2071-1050/15/4/2998/pdf (application/pdf)
https://www.mdpi.com/2071-1050/15/4/2998/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:15:y:2023:i:4:p:2998-:d:1060431
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().