EconPapers    
Economics at your fingertips  
 

Energy Measurement in Standard Penetration Tests

Peng Ji (), Jiling Yang, Nan Zhang, Qian Zhai, Minjie Li, Yueyi Wang, Tianlun Shen and Alfrendo Satyanaga
Additional contact information
Peng Ji: School of Civil Engineering, Southeast University, Nanjing 211189, China
Jiling Yang: School of Civil Engineering, Southeast University, Nanjing 211189, China
Nan Zhang: China United Engineering Corporation Limited, Hangzhou 310052, China
Qian Zhai: School of Civil Engineering, Southeast University, Nanjing 211189, China
Minjie Li: Nantong Keneng Monitoring Technology Co., Ltd., Nantong 226000, China
Yueyi Wang: School of Civil Engineering, Southeast University, Nanjing 211189, China
Tianlun Shen: School of Civil Engineering, Southeast University, Nanjing 211189, China
Alfrendo Satyanaga: Department of Civil and Environmental Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Kabanbay Batyr Ave., 53, Nur-Sultan 010000, Kazakhstan

Sustainability, 2023, vol. 15, issue 6, 1-15

Abstract: The standard penetration test (SPT) is a widely used in situ test method worldwide that can evaluate soil properties based on the blow counts ( N -value). The N -value depends on soil properties, and the energy transferred to the drill pipe during hammering. Currently, European and American scholars generally believe that variation in the amount of hammer energy transmitted to the drill pipe due to different types of drop hammer systems is the primary factor that leads to variations in N -value. In China, there is a lack of research on the quantitative energy transfer efficiency of the drop hammer system based on test data from a penetration test instrument. In this study, an in-situ test in Jiangsu Province was performed at a test site using standard penetration test instruments that are commonly used in China. Corresponding time history curves and strain, acceleration, force, velocity, energy and penetration degree data were obtained through the stress wave test. The propagation law of the stress wave and energy in a drill pipe was analyzed, and the energy transfer efficiency of the domestic SPT system was measured. In the stress wave test, most of the measured hammer energy efficiency was between 74.5 and 84.5%, and the measured average energy was 0.3723 kJ; the average energy efficiency was 78.7%; the standard deviation ( SD ) of the energy efficiency was 3.82, and the coefficient of variation ( CV ) of energy transfer efficiency( E R ) was 4.9%. The average energy efficiency of 78.7% can be considered to be the energy efficiency of the domestic SPT system. The calculated results reported in this article can be used to improve the quantitative level of domestic investigation. Based on the calculated E r , the results obtained from different SPT systems at home and abroad can be corrected.

Keywords: SPT; stress wave test; energy efficiency (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2023
References: View complete reference list from CitEc
Citations: View citations in EconPapers (5)

Downloads: (external link)
https://www.mdpi.com/2071-1050/15/6/4763/pdf (application/pdf)
https://www.mdpi.com/2071-1050/15/6/4763/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:15:y:2023:i:6:p:4763-:d:1090522

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:15:y:2023:i:6:p:4763-:d:1090522