EconPapers    
Economics at your fingertips  
 

The Use of Normative Energy Calculation beyond the Optimum Retrofit Solutions in Primary Design: A Case Study of Existing Buildings on a Campus

Wenjing Li, Zhuoyang Sun, Mehdi Makvandi, Qingchang Chen, Jiayan Fu, Lei Gong and Philip F. Yuan ()
Additional contact information
Wenjing Li: College of Architecture and Urban Planning, Tongji University, Shanghai 200092, China
Zhuoyang Sun: School of Urban Construction and Safety Engineering, Shanghai Institute of Technology, Shanghai 201418, China
Mehdi Makvandi: College of Architecture and Urban Planning, Tongji University, Shanghai 200092, China
Qingchang Chen: School of Urban Construction and Safety Engineering, Shanghai Institute of Technology, Shanghai 201418, China
Jiayan Fu: College of Architecture and Urban Planning, Tongji University, Shanghai 200092, China
Lei Gong: College of Architecture and Urban Planning, Tongji University, Shanghai 200092, China
Philip F. Yuan: College of Architecture and Urban Planning, Tongji University, Shanghai 200092, China

Sustainability, 2023, vol. 15, issue 9, 1-19

Abstract: There are significant differences between expectations and fulfillment in the building delivery process. Many researchers have emphasized the need for design strategies that establish a direct correlation between design proposals and building performance. One of the main objectives is to support performance-driven primary design, which occurs before the design performance modeling (DPM) phase. To achieve this, a case study of retrofitting existing buildings on campus is presented. A normative calculation approach is used to identify the optimal combinations of a dozen retrofit strategies based on the Energy Performance Calculator (EPC) model. This approach reduces or eliminates the impact of parametric uncertainties on modeling assumptions and simplifies calculations, particularly in restrictive studies. These retrofit solutions involve structural and functional zoning renovation, meaning that disparity between expectations and fulfilments is considered, and a timely related information feedback route to architects is achieved. In the first step of the narrative development of the EPC model, EPC-Calib was used to find the optimal combination of input variables in the model that satisfies the desired target and complies with the problem constraints. Secondly, the retrofit study was implemented with EPC-TechOpt, and 16 retrofit solutions for three design performance models were examined based on the local climatic conditions, building features, and retrofit costs. Finally, design schemes were determined, and the cost-optimal mix of the measures was desired with a 40% energy saving.

Keywords: primary design; energy-efficient retrofit; normative model; calculation calibration; strategic optimization approach (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/2071-1050/15/9/7094/pdf (application/pdf)
https://www.mdpi.com/2071-1050/15/9/7094/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:15:y:2023:i:9:p:7094-:d:1131039

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:15:y:2023:i:9:p:7094-:d:1131039