EconPapers    
Economics at your fingertips  
 

Application of the Heat Flow Meter Method and Extended Average Method to Improve the Accuracy of In Situ U-Value Estimations of Highly Insulated Building Walls

Ye-Ji Lee, Ji-Hoon Moon, Doo-Sung Choi and Myeong-Jin Ko ()
Additional contact information
Ye-Ji Lee: Department of Architectural Design and Engineering, Incheon National University, Incheon 22012, Republic of Korea
Ji-Hoon Moon: Department of Architectural Design and Engineering, Incheon National University, Incheon 22012, Republic of Korea
Doo-Sung Choi: Department of Building Equipment System and Fire Protection Engineering, Chungwoon University, Incheon 22100, Republic of Korea
Myeong-Jin Ko: Department of Building System Technology, Daelim University College, Anyang 13916, Republic of Korea

Sustainability, 2024, vol. 16, issue 13, 1-18

Abstract: In the context of remodeling old buildings, enhancing insulation performance in the exterior skin necessitates an accurate assessment of a wall’s thermal performance. The conventional method for determining the thermal transmittance (U-value) of a wall is the heat flow meter (HFM) as outlined in the ISO 9869-1. However, this measurement is susceptible to errors influenced by indoor and outdoor environmental conditions and the wall’s material composition. This study evaluates the U-value of an internally insulated wall, specifically constructed for this purpose, utilizing both the average and dynamic methodologies of an HFM. Furthermore, it introduces a novel estimation method: the extended average method (EXAM). The effectiveness of this proposed method is ascertained by comparing the accuracy and convergence of the U-value estimations with those derived from existing methodologies. Additionally, the study explores the limitations of the HFM by analyzing the heat flow traversing the interior of a wall. The findings revealed that the EXAM method enhanced the precision of U-value estimation in all scenarios. Particularly, in walls with superior insulation, the HFM tended to underestimate the heat flow observed indoors, leading to negative errors. The EXAM method, incorporating considerations of both insulation and structural materials, offers an accurate in situ measurement of the U-value relative to the HFM.

Keywords: thermal transmittance; average method; dynamic method; building exterior wall; extended average method (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/2071-1050/16/13/5687/pdf (application/pdf)
https://www.mdpi.com/2071-1050/16/13/5687/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:16:y:2024:i:13:p:5687-:d:1428301

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:16:y:2024:i:13:p:5687-:d:1428301