Performance Analysis of Lake Water Cooling Coupled with a Waste Heat Recovery System in the Data Center

Peng Yin, Yang Guo (), Man Zhang, Jiaqiang Wang (), Linfeng Zhang, Da Feng and Weike Ding
Additional contact information
Peng Yin: Jiangsu Communications Services Co., Ltd., Nanjing 210006, China
Yang Guo: School of Energy Science and Engineering, Central South University, Changsha 410083, China
Man Zhang: School of Energy Science and Engineering, Central South University, Changsha 410083, China
Jiaqiang Wang: School of Energy Science and Engineering, Central South University, Changsha 410083, China
Linfeng Zhang: School of Transportation, Southeast University, Nanjing 211189, China
Da Feng: China Telecom Corporation Limited Suzhou Branch, Suzhou 215025, China
Weike Ding: China Information Consulting & Designing Institute Co., Ltd., Nanjing 210019, China

Sustainability, 2024, vol. 16, issue 15, 1-21

Abstract: Data centers (DCs) require continuous cooling throughout the year and produce a large amount of low-grade waste heat. Free cooling and waste heat recovery techniques are promising approaches to reduce DC energy consumption. Although previous studies have explored diverse waste heat utilization strategies, there is a significant gap in combining waste heat recovery with lake water cooling in DCs. Therefore, this study proposed a system integrating lake water cooling with waste heat recovery for DCs. To evaluate the energy-saving performance of the suggested system, the influence of waste heat recovery locations and volumes has been investigated. An analysis of the improvement in system parameters is also conducted. The study’s findings highlight that targeted recovery of waste heat from sources like chilled water or air in server rooms can significantly reduce the cooling energy demand of the system. The results show that recovering heat from the return air of IT equipment can yield a remarkable power usage effectiveness (PUE) and coefficient of performance (COP) of 1.19 and 10.17, and the energy consumption of the cooling system is reduced to 10.06%. Moreover, the outcomes reveal the potential for substantial energy savings of up to 26.05% within the proposed system by setting the chilled water and air supply temperatures to 16 and 20 °C, respectively.

Keywords: data center; lake water cooling; waste heat utilization; performance analysis; energy saving (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/2071-1050/16/15/6542/pdf (application/pdf)
https://www.mdpi.com/2071-1050/16/15/6542/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:16:y:2024:i:15:p:6542-:d:1446666

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:16:y:2024:i:15:p:6542-:d:1446666