EconPapers    
Economics at your fingertips  
 

Analysis of the Cooperation of a Compressor Heat Pump with a PV System

Krzysztof Tomczuk () and Paweł Obstawski
Additional contact information
Krzysztof Tomczuk: Institute of Mechanical Engineering, Warsaw University of Life Sciences, Nowoursynowska St. 164, 02-787 Warszawa, Poland
Paweł Obstawski: Institute of Mechanical Engineering, Warsaw University of Life Sciences, Nowoursynowska St. 164, 02-787 Warszawa, Poland

Sustainability, 2024, vol. 16, issue 9, 1-29

Abstract: The decarbonization of heating systems is one of the present political and legislative directions of the European Union and its Member States. The main activities concern the energy performance of buildings and energy efficiency. The mentioned UE directives are the basis for the financial support of high-emission fossil fuel thermal energy source replacement with emission-free ones, in particular heat pumps. Other aspects are the support of PV installations and the thermal insulation of buildings. 85% of EU buildings were built before 2000, and among those, 75% have poor energy performance. Therefore, a significant number of buildings have only high-temperature wall radiators, and this was a motivation to prepare this article. The main innovation of this research was a new theoretical design of a high-temperature heat pump based on ecological refrigerants. The presented solution allows wall radiators to receive a hot water supply with temperatures of up to 85 °C during external temperatures of up to −20 °C. Typical heat pumps do not have these kinds of parameters, so the authors decided to verify the possibility of operating this device in such a wide temperature range. Another important aspect was the analysis of PV support. Finally, this paper investigates the possibility of heating an energy-efficient house with the newly designed high-temperature heat pump. Depending on the location in Poland, i.e., Suwałki, Warsaw, and Wrocław, the total electric energy supplied to the compressors was 2538–3364 kWh. The energy provided by the PV to supply power to the compressors is 482–570 kWh. The achieved PV energy self-consumption is 16.9–19.0%. The Seasonal Coefficient of Performance (SCOP) of the heat pump is 1.825–2.038 without PV and 2.515–2.970 with PV.

Keywords: heat pump; PV system; hybrid power system; energy storage (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/2071-1050/16/9/3797/pdf (application/pdf)
https://www.mdpi.com/2071-1050/16/9/3797/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:16:y:2024:i:9:p:3797-:d:1386993

Access Statistics for this article

Sustainability is currently edited by Ms. Alexandra Wu

More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jsusta:v:16:y:2024:i:9:p:3797-:d:1386993