Blue Light Hazard and Risk Group Classification of 8 W LED Tubes, Replacing Fluorescent Tubes, through Optical Radiation Measurements
Francesco Leccese,
Viola Vandelanotte,
Giacomo Salvadori and
Michele Rocca
Additional contact information
Francesco Leccese: LIghting and Acoustic Laboratory (LIA), Department of Energy engineering, Systems, Territory and Construction (DESTeC), University of Pisa, Largo Lucio Lazzarino, 56122 Pisa, Italy
Viola Vandelanotte: Department of Energy Engineering, Faculty of Engineering Technology, KU Leuven, Technology Campus-Ghent, 9000 Ghent, Belgium
Giacomo Salvadori: LIghting and Acoustic Laboratory (LIA), Department of Energy engineering, Systems, Territory and Construction (DESTeC), University of Pisa, Largo Lucio Lazzarino, 56122 Pisa, Italy
Michele Rocca: LIghting and Acoustic Laboratory (LIA), Department of Energy engineering, Systems, Territory and Construction (DESTeC), University of Pisa, Largo Lucio Lazzarino, 56122 Pisa, Italy
Sustainability, 2015, vol. 7, issue 10, 1-15
Abstract:
In this paper, the authors discuss the results of a measurement survey of artificial optical radiation emitted by 8 W LED tubes suitable for the substitution of 18 W fluorescent lamps used for general lighting. For both types of lamps, three different color temperatures were chosen, 3000 K, 4000 K, and 6000 K. These measurements were performed to evaluate the photobiological safety of the sources. The radiance and irradiance values have been measured in a wide range of wavelengths (180–3000 nm). The measurement results obtained for the LED tubes have been compared to those of similar measurements obtained for fluorescent lamps. The analysis has been focused on the range of wavelengths 300–700 nm, the blue light range, which turned out to be defining for the risk groups of the lamps. This classification is a function of the maximum permissible exposure time as indicated in the European Standard EN 62471 on the photobiological safety of lamps and lamp systems.
Keywords: artificial optical radiation; LED tubes; fluorescent lamps; blue light hazard; maximum permissible exposure time; risk group (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2015
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (5)
Downloads: (external link)
https://www.mdpi.com/2071-1050/7/10/13454/pdf (application/pdf)
https://www.mdpi.com/2071-1050/7/10/13454/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:7:y:2015:i:10:p:13454-13468:d:56623
Access Statistics for this article
Sustainability is currently edited by Ms. Alexandra Wu
More articles in Sustainability from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().