EconPapers    
Economics at your fingertips  
 

Analysis of the Performance of Vacuum Glazing in Office Buildings in Korea: Simulation and Experimental Studies

Soo Cho and Seok-Hyun Kim
Additional contact information
Soo Cho: Korea Institute of Energy Research, 152 Gajeong-ro, Yuseong-gu, Daejeon 34101, Korea
Seok-Hyun Kim: Department of Architectural Engineering, Graduate School of Yeungnam University, 280 Daehak-ro, Gyeongsan 38541, Korea

Sustainability, 2017, vol. 9, issue 6, 1-15

Abstract: Window performance in buildings is very important for energy saving. Many efforts have been made towards saving energy in buildings, and research has focused attention on enhancing the thermal performance of windows. Vacuum glazing has attracted much interest as a means of enhancing the thermal performance of windows by strengthening insulation performance. However, the performance of vacuum glazing differs based on various component combinations, therefore, further study on vacuum glazing is needed. In this paper, through simulations, the authors confirmed the heat transfer value (U-value) of the vacuum glazing composed of various combinations (glass type, number of layers, interval of pillar, etc.). A physical test of vacuum glazing was also performed using standard test methods of windows and the U-value of the vacuum glazing by various intervals of the pillar position was confirmed. The simulation revealed a U-value for vacuum glazing of 0.682–1.466 W/m 2 ·K as per the interval of the pillar position, the performance of solar heat gain, and visible light transmission. The U-value of the double vacuum glazing was calculated as 0.607–1.154 W/m 2 ·K and was similar regardless of the interval of pillar position, the performance of solar heat gain, and visible light transmission. Based on the results of the energy simulation, in the case of a used low U-value of vacuum glazing, the heating and cooling energy consumption in buildings decreased by 2.46%, than when low-e glass and argon gas filled layers were used in windows. Furthermore, in double vacuum glazing, the heating and cooling energy consumption in buildings decreased by 3.91%.

Keywords: vacuum glazing; U-value; energy consumption; energy simulation (search for similar items in EconPapers)
JEL-codes: O13 Q Q0 Q2 Q3 Q5 Q56 (search for similar items in EconPapers)
Date: 2017
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (4)

Downloads: (external link)
https://www.mdpi.com/2071-1050/9/6/936/pdf (application/pdf)
https://www.mdpi.com/2071-1050/9/6/936/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jsusta:v:9:y:2017:i:6:p:936-:d:100370