EconPapers    
Economics at your fingertips  
 

Study on the Influencing Factors of Insulator on the Back-Flashover Lightning Withstand Performance of ±800 kV UHVDC Transmission Lines

Wenbo Jiang, Chunlin Tang and Bo Zhou

Mathematical Problems in Engineering, 2020, vol. 2020, 1-15

Abstract:

The current research results indicate that the insulator’s insulation performance has a very important influence on the back-flashover lightning withstand performance of UHVDC transmission lines, especially for ±800 kV voltage level. However, it is not clear which factors will influence the insulation performance of the insulator, and the influencing mechanism is also not clear yet. To figure out this problem, the insulator’s insulation performance under different conditions has been deeply analyzed and considered to reveal the influence mechanism in this paper, such as the surface hydrophobicity, pollution degree, and the string type. Firstly, the insulator’s model is established using COMSOL software, and the lightning impulse voltage of insulator is calculated and verified with the corresponding experimental data. Then, the ±800 kV UHVDC transmission lines model is constructed using PSCAD software, and back-flashover lightning withstand level and back-flashover rate are calculated by considering the above lightning impulse voltage as the threshold of flashover. Finally, the back-flashover lightning withstand performance of ±800 kV UHVDC transmission lines is deeply analyzed based on different insulators. The simulation results demonstrate that the back-flashover lightning withstand performance of ±800 kV UHVDC transmission lines is obviously weakened with the increase of the pollution degree and slightly weakened with the decrease of the surface hydrophobicity. Considering the same pollution degree, the V-type string insulator has the least influence, while the II-type string insulator has the greatest influences on the back-flashover lightning withstand performance of ±800 kV UHVDC transmission lines. The research results are beneficial for providing theoretical basis for stable operation and reliable power supply of ±800 kV UHVDC transmission lines.

Date: 2020
References: Add references at CitEc
Citations:

Downloads: (external link)
http://downloads.hindawi.com/journals/MPE/2020/5021408.pdf (application/pdf)
http://downloads.hindawi.com/journals/MPE/2020/5021408.xml (text/xml)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:hin:jnlmpe:5021408

DOI: 10.1155/2020/5021408

Access Statistics for this article

More articles in Mathematical Problems in Engineering from Hindawi
Bibliographic data for series maintained by Mohamed Abdelhakeem ().

 
Page updated 2025-03-19
Handle: RePEc:hin:jnlmpe:5021408